Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0524-00872
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/06/2024 | Commercial Electrical | APPROVED | |||
06/12/2024 | Commercial Mechanical | APPROVED | |||
06/12/2024 | Commercial Structural | APPROVED | |||
06/04/2024 | Site Zoning | APPROVED | |||
06/05/2024 | Site Engineering | NOT REQUIRED | |||
06/12/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/12/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Verify that the specified sensor faucets for the restroom lavatories have an automatic time-out so that they will dispense a maximum of 0.25 gallons per metering cycle (e.g. 0.5 GPM for 10 to 30 seconds). Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Provide tempered water for the public restroom lavatories using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2018. |
||
06/12/2024 | Water - PDSD | REQUIRES RESUBMIT | Provide the size of the water meter serving this building, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018. | ||
05/26/2024 | Fire New Construction | REVIEW COMPLETED | |||
05/09/2024 | PDSD Application Completeness | REVIEW COMPLETED |