Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0524-00787
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/03/2024 | Site Zoning | APPROVED | |||
06/04/2024 | Site Engineering | NOT REQUIRED | |||
06/06/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
05/23/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 5/21/2024 1:31:35 PM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/21/2024 3:17:28 AM Sheet G1.0 1. Provide a location map on the cover sheet in accordance with the building plan general requirements per the City of Tucson. 2. Update the sheet index so it matches the drawings that were provided in the set. Correct the sheet arrangements so that the title sheets are at the beginning of the set, not in the middle. 3. Include the International Mechanical Code 2018 on the list of governing codes. 4. Indicate the building classification alternation level on the drawings in accordance with the International Existing Building Code Chapter 6. 2018 IEBC 601.1. 5. Clarify if the area will be provided with an automatic fire sprinkler and fire alarm system in accordance with 2018 IEBC 803. The plans indicate that there is no current fire sprinkler system present in the building. 6. Indicate on the life safety plan the required minimum egress width, required number of exits to be provided, and the maximum travel distance from the most remote point. 2018 IBC Sections 1005, 1006, 1017. 7. Provide an overall section through the building and indicate the heights as well as the existing structure of the building. 2018 IBC 107 and City of Tucson building plan requirements. ◦ Sheet G1.02 8. Clarify the note 1 that indicates to “Refer to the PDS American Sheets for ADA accessible clearances”, this sheet was not found in the set. 9. Indicate on the drawings that Fire extinguishers shall be installed in accordance with 2018 IFC Section 906.2. 10. Note on the drawings that the tenant fire separation will be maintained. Walls separating tenants shall be of a 1-hour fire rated assembly and shall act as a fire barrier. 2018 IBC 708.1. ◦ Sheet A1.01 11. Clarify what will be the use of the rooms noted as “Enclave” on the drawings shown off the waiting area. The furniture drawing F2.0 shows this area to have a desk and two chairs however the chairs appear to be positioned in the sliding doorway. ◦ Sheet A2.51 12. Indicate the size of the cased opening and show a turning radius for the area between the two “Waiting Toilets” rooms on the enlarged floor plans detail 9. ICC A117.1-2009. ◦ Sheet F0.01 13. Indicate on the finish schedule that all interior finishes will be in accordance with 2018 IBC 803.1. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 5/20/2024 2:19:38 PM 1. General - Provide Ventilation calculation/Schedule - 2018 IMC table 403.3.1.1 - Engineer Analysis: ASHRAE 62.1 and 90.1 Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 5/9/2024 6:03:08 PM 1. E0.02 ELECTRICAL POWER DISTRIBUTION & SCHEDULES: Power Distribution Diagram implies that H2 is in a different room or far location from transformer T-L2 and Panel L2. Circuits for power and lighting and the panel schedule imply that the panel is actually Panel L1. Rename transformer and Panel on this sheet or where necessary for coordination. Existing equipment and new equipment shall not have the same names. 2. Comment for sheet E3.01 ELECTRICAL POWER: New transformer and Panel in the electrical room do not match what is shown by the Power distribution diagram on sheet E0.02. Correct, clarify or coordinate. 3. Comment for sheet E6.01 ELECTRICAL PANEL SCHEDULES: Panel L1 does not match name of new panel shown on Sheet E0.02. Coordinate/correct as required. 4. Comment for sheet E6.01 ELECTRICAL PANEL SCHEDULES: Panel L1 shows power fed from T-L1 not from T-L2 as called out on sheet E0.02. Coordinate/correct as required. 5. Comment for sheet E6.01 ELECTRICAL PANEL SCHEDULES: If Panel L1 is within sight of primary disconnect (panel H2?) it is NEC compliant (as shown by E3.01 and if L1 is fed from T-L1 (as shown by Panel schedule H2). However, sheet E0.02 and Sheet E3.01 do not seem to be coordinated. Design needs to comply with NEC 240.21 and 450.3B if Overcurrent protection and disconnect for transformer are in different locations. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/22/2024 8:07:00 PM First plumbing review: 1). General: Plans missing plumbing fixture count table with occupancy types & loads. Add a plumbing fixture count table to plan set-in accordance with 2018 IPC 403.1 |
||
05/30/2024 | Fire New Construction | REQUIRES RESUBMIT | -Resolve all building comments. john.vincent@tucsonaz.gov 5203495581 |
||
06/06/2024 | Water - PDSD | REQUIRES RESUBMIT | 1. Coordinate the location of the water service to the suite. Sheet C2.0 shows the entrance at the Northwest corner of the suite while sheet P2.01 shows the entrance at what is actually the Southwest corner of the suite. (The North arrows for the architectural, electrical, mechanical, and plumbing drawings are incorrect). 2. Reduced pressure backflow prevention assemblies protecting the municipal water distribution system are required to be installed in locations accessible to Tucson Water (see P2.01 and C2.0). Provide a letter from Tucson Water confirming that installation of the backflow preventer will be allowed inside the building. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf 3. Provide the total water demand for the suite. Reference: Section 107.2.1, IBC 2018. |
||
05/08/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |