Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0523-01396
Parcel: 140560150

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0523-01396
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/15/2023 Commercial Building REQUIRES RESUBMIT Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed.
1. Your State Application Draft selected Behavior Health Respite Home which does not match the description of your services. Did you mean to select Behavioral Health Residential Facility?
2. R-4 Occupancy allows maximum of 10 per City of Tucson Amendment.
Please correct occupancy to 10 max.
3. Accessible bathroom requires door clear opening of 32 inches minimum. Provide grab bars at the water closet and shower. The 5 ft clearance is not met at the sink. Please comply to the accessibility requirement.
4. Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. IBC 1030.2 The minimum net clear opening height dimension shall be 24 inches. The minimum net clear opening width dimension shall be 20 inches. IBC 1030.2.1 Emergency escape and rescue openings shall have the bottom of the clear opening not greater than 44 inches measured from the floor. IBC 1030.3
5. Please resubmit.
11/15/2023 Fire New Construction REQUIRES RESUBMIT Increased occupant load (from previous zoning approval) will require approval from zoning before fire review.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
10/23/2023 PDSD Application Completeness Express REVIEW COMPLETED