Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01384
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/27/2023 | Water - PDSD | APPROVED | |||
| 06/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/12/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01384 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Conditionally Approved Reason: Date Completed : 6/10/2023 3:59:35 AM no structural work was included in this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/10/2023 3:56:59 AM 1. Clarify if the existing trellis and columns that are in the way of the new walk-in cooler will be demolished as part of this permit. If so, include it on the drawings. 2. The masonry enclosure detail on sheet A5 indicates the footing for the new wall (where the existing trellis is located) however there is no plan nor any information if the existing sidewalk/ slab area is sufficient to hold the new walk-in coolers. Provide a foundation/concrete slab plan for the work. 3. Provide construction details for the new walls and door frames to be installed in the existing office/ dry storage area. 4. Provide dimensions for the new walls and doors for the office/ dry storage room. Show the distance between the new shelving as well as the required door clearances for accessibility for the new doors. 5. Indicate the required accessible door clearance of 12” on the latch side for the existing door to the exterior yard that is being replaced. ICC A117.1 -2009 Figure 404.2.3.2. 6. Provide a door and hardware schedule for the new barn door, office/ dry storage and the replaced door to the exterior yard. 7. Include the lighting in the office/ dry storage area and any changes to the existing ceiling on the partial ceiling plan sheet A6. Clarify if there was an existing exhaust fan in the restroom that will need to be removed as well. Coordinate with the MEP drawings. 8. Provide details for the new built-in desk that is in compliance with ICC A117.1 -2009. Include the height and method of attachment to the existing wall. 9. Indicate on the drawings that fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Conditionally Approved Reason: Date Completed : 6/10/2023 3:59:07 AM exhaust hood fire suppression system to be provided under differed submittals Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/10/2023 3:58:11 AM 1. Indicate the lighting in the existing office/ dry storage area that is being modified on the drawings. Show and existing light for the exterior yard on the drawings to illuminate the new cooler area or show a new light that is in compliances with the City of Tucson/ Pima County Outdoor Lighting Code. 2. Indicate any new or relocated receptacles for the office/ dry storage area. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/10/2023 2:02:15 PM First Plumbing Review: 1). Plan pages P2, & P3 show 2 floor sinks near water softeners , Plan page P1 only shows one floor sink in that area. Plan pages need to correlate -IPC 106.3.1 |
||
| 06/08/2023 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
| 05/31/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0523-01384 6202 East Broadway Boulevard – C-1 Food Service tenant improvement (1st Review) TRANSMITTAL DATE: May 31, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Per UDC 3.3.3.G.2.c, as you are proposing building additions and ultimately increasing the gross floor area of an existing nonresidential development, a development package that meets the Checklist for Minor Development Changes to Existing Commercial/Industrial Sites is required to be submitted, reviewed, and approved prior to zoning approval of this building permit. The development package is a separate submittal and shall be applied for under application type “Development Package” on the Tucson Development Center Online. If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov. |
||
| 05/31/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |