Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01364
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/27/2023 | Water - PDSD | APPROVED | |||
06/08/2023 | Site Engineering | NOT REQUIRED | |||
06/27/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/09/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01364 GENERAL: ⦁ Provide written responses to all review comments. ⦁ Provide a complete plan set. ⦁ Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Conditionally Approved Reason: Date Completed : 6/9/2023 7:31:09 AM no structural work was included with this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/9/2023 7:27:56 AM 1. The plans indicate this is to be a warehouse, however the definition of a warehouse is to store goods and raw materials. This does not match the intended use of the space as described on sheet A0.0. Indicate the actual use on the drawings and update all sheets. The definition of a repair garage per IBC is a building used for servicing or repairing motor vehicles which appears to be closer to the actual intended use. 2. Remove the accessibility bathroom details on sheet 1.1 as well as the details on sheet A4.0 that do not apply to this project or indicate on the drawings that they are “not used”. 3. Update the key notes on sheet A6.0 that indicates to see the water heater platform detail 8 on sheet A4.0, the correct detail is 5. Coordinate with the water heater detail on sheet P1.0. 4. Indicate that the overhead door type C on sheet 5 is existing if it was built with the development plan under a separate permit. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/9/2023 7:28:51 AM 1. Provide mechanical ventilation in the area in which vehicles will be worked on including a gas detection system in accordance with 2018 IBC 406.8. The only ventilation is shown in the storage room. Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/9/2023 7:28:21 AM 1. Update the general notes on sheet E1.0 to match the project. note a indicates to convert a shell building to warehouse and offices. Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/9/2023 7:30:42 AM 1. Clarify if the new space is to only install film or if the cars will be detailed and washed in the space as well. If the work includes discharge of oil, grease, sand, or other substances such as chemicals into the public sewer, a floor drain to an oil separator will be required. 2018 IPC section 1003.1 and 1003.4. |
||
06/06/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0523-01364 7206 N. Silverbell Rd., Bldg 4 Unit 4140 – C-1 TI – Commercial Storage (1st Review) TRANSMITTAL: June 06, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-1 Zone (UDC 4.7.20). Commercial Storage is not an allowed use in the zone, (UDC Table 4.8-4). Based on the use shown on the plan “WAREHOUSE” which equates to Commercial Storage for Zoning purposes the proposed use is not allowed in the C-1 Zone. Based on the Car Kulture web page, https://carkulturetucsonaz.com, Car Kulture is an Automotive - Minor Service and Repair use. Automotive - Minor Service and Repair is an allowed use in the zone subject to Use Specific Standards 4.9.4.F.2, .3, .4, & .5 and 4.9.13.O and a Zoning Examiner Special Exception Procedure, Section 3.4.3. The Special Exception must be approved prior to approval of this building plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/31/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/25/2023 | PDSD Application Completeness | REVIEW COMPLETED |