Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01277
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/26/2023 | Site Zoning | APPROVED | |||
05/31/2023 | Site Engineering | NOT REQUIRED | |||
06/02/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/02/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01277 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Conditionally Approved Reason: Date Completed : 6/2/2023 2:23:25 AM no structural work has been included in this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/2/2023 2:21:54 AM 1. Verify the actual cost for the project, the submittal indicates $26,000.00 which appears to be low based on the submitted drawings. 2. Indicate a landing or sidewalk on the exterior of the new rear exit door and roll-up door. If a new landing or sidewalk is to be installed, provide details and dimensions for its construction. 3. Clarify if the roll-up door is a new door to be installed into an existing opening with a new window above. The electrical drawings indicate this door is existing. If this is a new door, provide details for its installation. 4. Provide exterior door details for the new exterior door including the header and threshold, only construction details for the interior doors were indicated on sheet A4.0. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/2/2023 2:22:42 AM 1. Provide a roof plan for the mechanical units and indicate if the new mechanical units will be within 10 feet of the roof edge. If so, indicate how fall protection will be provided in accordance with the IMC and 2018 IBC 1015.6. Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/2/2023 2:22:19 AM 1. Indicate the location of an existing emergency light on the exterior at the exit doors to illuminate the landings or indicate new fixtures will be provided. 2018 IBC 1008.3.2 (5). 2. Clarify if the new electrical sub panel is surfaced mounted or if the existing wall is not required to be rated and the panel will be set in the stud space. The wall detail 6 and the partition notes on sheet A2.0 appears to show this as an existing rated wall between tenant spaces. Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 6/2/2023 2:22:59 AM |
||
05/26/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/18/2023 | PDSD Application Completeness | REVIEW COMPLETED |