Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0523-01249
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/27/2023 | External Reviewers - SAFEBuilt | APPROVED | Activity Number: TC-COM-0523-01249 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 6/3/2023 1:37:52 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 5/26/2023 10:55:57 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/26/2023 11:01:56 PM 1. Provide ventilation calculations (IMC2018,403.3.1.1.1) Complied 2. Provide gas piping riser plan, with the gas pressure at the point of delivery, and the design pressure drop, maximum gas demand and specific gravity of the fuel gas and the total pipe length from the meter to the farthest appliance. Showing all gas appliances from the meter to the furthest appliance (IFGC2018,402.3) Complied Approved/Subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 5/26/2023 2:04:06 PM Electrical Review By: Ron Ross PE E702: There are two Keyed Note #6 notes. E801B: Could not locate Keyed Note #6. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 6/26/2023 11:02:39 PM Second plumbing Review: OK subject to field inspections 1). OK 2). OK 3). OK- Plumbing plan pages P203 & P204 are missing from plan set but listed on plan sheet index page G001? -IPC 106.3.1 **Plan page M001 sheet list doesn't show these pages, subject to field inspections** 4). OK 5). OK |
||
06/29/2023 | Bldg Permits - Post Review | REVIEW COMPLETED | |||
06/29/2023 | Fire New Construction | REVIEW COMPLETED | |||
06/24/2023 | PDSD Application Completeness | REVIEW COMPLETED |