Permit Number: TC-COM-0523-01240
Parcel: 13728107B

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0523-01240
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT TC-COM-0423-01167, TC-COM-0523-01240, TC-COM-0523-01241, TC-COM-0523-01242 SHARE PLANS
Studio Session 829-086-124 On (TC-COM-0423-01167)
07/11/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Activity Number:
TC-COM-0423-01167 991 W MELROSE ST - LEASING OFFICE
TC-COM-0523-01240 991 W MELROSE ST - BLDG A/5 UNIT
TC-COM-0523-01241 991 W MELROSE ST - BLDG B/4 UNIT
TC-COM-0523-01242 991 W MELROSE ST - BLDG C/5 UNIT


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 5/31/2023 4:51:38 PM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.



Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 6/26/2023 3:52:45 PM



Mechanical(M) Reviewer
Neil Samaan
nsamaan@safebuilt.com
Denied
Reason:
Date Completed : 6/26/2023 10:53:23 PM
1. Where bathroom, dryer, kitchen exhaust duct's and outdoor fresh air duct penetrates the fire rated floor/ceiling assembly it shall be protected in an approved manner in accordance with this section in all apartment unit's (IMC2018,607.6.2) The section in voolation is 607.6.2 not 607.5.3 as is your response Not Complied
2. Provide ceiling radiation dampers at all ceiling supply diffuser's, provide the symbol on the plan and note it on the same page in all apartment unit's (IMC2018,607.6.2) Same as #1 Not Complied
3. Only fire dampers and ceiling radiation dampers labeled for use in dynamic systems shall be installed in HVAC systems designed to operate with fans on during a fire event in all apartment units (IMC2018,607.3.1) Not Complied
4. Provide kitchen exhaust to building D IMC2018,403.3) Complied
5. Provide make up air for laundry room approximately equal the the total dryer exhaust rate in an approved manner (IFGC2018,614.5) Complied



Electrical(E) Reviewer
Matthew Payette
mpayette@safebuilt.com
Approved
Reason:
Date Completed : 7/10/2023 3:47:57 PM



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 6/26/2023 10:43:43 PM
Second plumbing Review:**OK SUBJECT TO FIELD INSPECTIONS.**
1). OK - Roof parapet wall on plan pages A1.14, A1.24, A1.34, A1.42 needs secondary scuppers compliant with IPC 1106.5 & 1108, ** Secondary scupper detailed added to each page**
2). OK
3). OK
4). OK- Plan set submittal needs to be accompanied by the civil site utility piping plan for the continuation & correlation of the water, storm & sewer. -IPC 106.3.1 ** PER ARCHITECT RESPONSE COMMENTS, THIS CIVIL SET SET IS NOT PART OF THIS APPROVAL PACKAGE AND HAS ALREADY BEEN APPROVED BY TUCSON** **OK SUBJECT TO FIELD INSPECTIONS.**
5). OK
6). OK
07/05/2023 Site Engineering REQUIRES RESUBMIT See zoning comment
06/28/2023 Site Zoning REQUIRES RESUBMIT TC-COM-0423-01167, TC-COM-0523-01240, TC-COM-0523-01241, TC-COM-0523-01242 SHARE PLANS
Studio Session 829-086-124 On (TC-COM-0423-01167)

FROM: PDSD Zoning Review Section

PROJECT: TC-COM-0423-01167 – Leasing Office, TC-COM-0523-01240 – Bldg A, TC-COM-0523-01241 – Bldg B & TC-COM-0523-01242 – Bldg C
8411 S. Houghton Rd – R-2
Multifamily (2nd Review)

TRANSMITTAL DATE: ‎June 28, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in the zone, (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. COMMENT: Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0123-00111 and although it appears that the plans match until the DP is approved by all review agencies Zoning cannot approve the building plans.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/23/2023 PDSD Application Completeness Express REVIEW COMPLETED