Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0523-01176
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/26/2023 | Site Engineering | APPROVED | |||
05/30/2023 | Site Zoning | APPROVED | |||
06/15/2023 | Water - PDSD | APPROVED | |||
06/16/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/16/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01176 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved with Comments Reason: Date Completed : 6/16/2023 3:18:25 PM no structural work was included as part of this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/16/2023 3:17:11 PM 1. Update the cover sheet and drawing address titles to indicate the correct suite number if this set of pans does not include the cinnaholic space. note on the drawings that the cinnaholic space and new demising wall is under a separate permit. It is ok to leave the information on the plans if they are corrected as noted in the original plan review for TC-COM-00175 done previously. 2. Add sheet P3.0 to the sheet index on sheet A0.0, it is missing but was provided as part of the set. 3. Update the summary of governing regulations on sheet A0.0 to indicate ICC A117.1- 2009 for the accessibility code, not 2017. 4. Update the general building summary and occupant loads shown on sheet A0.0, the bakery should be a type B occupancy per 2018 IBC 303.1.1 not type M. Update the exit plan and indicate the occupancy count for the front area based on 2018 IBC 1004.5. 5. Clarify if this is a partial buildout for the bakery and a separate permit will be submitted for the IT of the restaurant. The floor plan on sheet A2.0 indicates both spaces as vacant and no equipment or furnishings were provided for the new bakery. 6. Provide a detail for the new demising wall A where it intersects with the existing storefront, this appears to be tied into a window. 7. Clarify that the new demising wall type A is only to go 6” above the ceiling and not go to the underside of the roof deck. 8. Indicate fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. 9. Note on the drawings that any openings, existing or new within the fire rated barrier will be filled to match or exceed the fire rating of the wall. 2018 IBC 714. 10. Update the accessibility details on sheet A5.0 that indicate ADA to ICC ANSI A117.1 in the details title or simple indicate “accessible water closet” for example Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/16/2023 3:17:53 PM 1. Update the cover sheet and drawing address titles to indicate the correct suite number if this set of pans does not include the cinnaholic space. note on the drawings that the cinnaholic space and new demising wall is under a separate permit. It is ok to leave the information on the plans if they are corrected as noted in the original plan review for TC-COM-00175 done previously. Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/16/2023 3:17:42 PM 1. Update the cover sheet and drawing address titles to indicate the correct suite number if this set of pans does not include the cinnaholic space. note on the drawings that the cinnaholic space and new demising wall is under a separate permit. It is ok to leave the information on the plans if they are corrected as noted in the original plan review for TC-COM-00175 done previously. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/14/2023 9:02:45 PM First Plumbing Review: 1). Cover sheet & scope states tenant improvement, Permit description states TC-COM-0523-01175 is Shell permit, both submittals appear to be the same plan set? -IPC 106.3.1 2). Mercantile occupancy load 33 requires high/low drinking fountain & service sink in bakery side, the plumbing pages do not reflect those required fixtures & piping illustrations -IPC 403.1 3). plumbing piping plans do not reflect any kitchen cooking equipment, prep sinks, hand sinks , grease interceptor, gas piping etc. -IPC/IFGC 106.3.1 4). Elevated water heater on plan page P2.0 requires a pan & drain piped to a waste receptor or exterior. -IPC 504.7.1, 504.7.2 5). one of the Sanitary connection points is flowing in the incorrect direction on plan page P1.0 - IPC 706.3 |
||
05/30/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/15/2023 | PDSD Application Completeness | REVIEW COMPLETED |