Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0523-01176
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2023 Bldg Permits - Post Review PENDING ASSIGNMENT TC-COM-0523-01175 & TC-COM-0523-01176 SHARE PLANS
06/26/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT TC-COM-0523-01175 & TC-COM-0523-01176 SHARE PLANS

Activity Number: TC-COM-0523-01176

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

Structural(S) Reviewer
Janet Matz
jmatz@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 6/16/2023 3:18:25 PM
no structural work was included as part of this submittal


Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 6/24/2023 8:23:18 PM
Sheet A0.0 scope of work does not provide any deferred submittals. Are fire sprinkler system and/or alarm deferred submittals?
Sheet A0.0 code review does not indicate fire alarm system (Y or N)?
Sheet A0.0 code review shows note about use of combustible materials for “Type ll” while type of construction states Type VB.
Sheet A2.0 floor plan tags new demising all type A which in wall type schedule is for “existing wall”. A1 wall type is not identified in wall schedule. Keynote 4 shows to “provide type ‘x’ gypsum board at all rated partitions” while not used in any wall types. Provide UL assembly number when providing rated partitions. If future tenant is uncertain and code review defining as “Separated uses/Y” then 2018 IBC Table 508.4 still requires 1 hour for B and A-2 (E.g. Restaurant) in sprinklered building. Provide penetration details when rated partition is applicable.


Mechanical(M) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 6/24/2023 8:24:13 PM
"...work on this project involves only the suite shell preps for both suite 135 & 145 and that any additional work for either suite will be through a future permit submittal."

Electrical(E) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 6/24/2023 8:23:55 PM
"...work on this project involves only the suite shell preps for both suite 135 & 145 and that any additional work for either suite will be through a future permit submittal.


Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 6/25/2023 12:01:26 PM
Second Plumbing Review:
1). SAME- Cover sheet & scope states tenant improvement, Permit description states TC-COM-0523-01175 is Shell permit, both submittals appear to be the same plan set? -IPC 106.3.1 ** If this is shared plan, upload the updated TC-COM-0523-01175 plan to this record**
2). SAME -Mercantile occupancy load 33 requires high/low drinking fountain & service sink in bakery side, the plumbing pages do not reflect those required fixtures & piping illustrations -IPC 403.1 ** The plan set with this record still shows Mercantile 33**
3). SAME-plumbing piping plans do not reflect any kitchen cooking equipment, prep sinks, hand sinks , grease interceptor, gas piping etc. -IPC/IFGC 106.3.** The plan set with this record still shows same scope that includes tenant improvements**
4). SAME-Elevated water heater on plan page P2.0 requires a pan & drain piped to a waste receptor or exterior. -IPC 504.7.1, 504.7.2** The plan set with this record doesn't show compliance**
5). SAME-one of the Sanitary connection points is flowing in the incorrect direction on plan page P1.0 - IPC 706.3** The plan set with this record doesn't show compliance**
06/22/2023 PDSD Application Completeness REVIEW COMPLETED