Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01174
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2023 | Site Engineering | APPROVED | |||
| 05/17/2023 | Site Zoning | APPROVED | |||
| 06/15/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/15/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01174 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Conditionally Approved Reason: Date Completed : 6/15/2023 3:27:39 AM no structural work was included in this submittal Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/15/2023 3:26:50 AM 1. Provide a life safety/ exit plan for the front service counter and kitchen on the drawings that indicate the travel distances from the most remote points the minimum widths and the occupant loads in accordance with 2018 IBC 1004 and 1017.2. The new wall configuration will increase the exiting distance through the front area slightly. 2. Provide a clear opening dimension on the floor plan A1.0 on the south side of the new #9 center island to the parallel wall and the front of the new #16 hand sink. (The plumbing plan sheet P1 shows the equipment located next to the hand sink). 2018 IBC 1005.2. 3. Provide an accessible path from the customer area through the customer service employee area and the area by the relocated hand sink. Common use circulation paths within employee work area shall be accessible per 2018 IBC 1104.3.1 and ICC A117.1 403.5/ 304.3. 4. Clarify if the use for the existing closet where the door is being reversed. Indicate if it is for storage of items or if it is mechanical/ electrical equipment not needed to be accessible. ICC A117.1 Figure 404.2.3.2. 5. Indicate on the drawings that Fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. 6. Indicate on the finish schedule that all interior finishes will be in accordance with 2018 IBC 803.1. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 6/15/2023 3:27:12 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 6/15/2023 3:27:02 AM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/12/2023 10:48:41 PM First Plumbing Review: 1). Lav/sink Temperature Note #3 on plan page P1.0 needs to comply with -IPC 607.1.2 2). Beverage equipment water connections on P1.0 needs to be illustrated along with backflow device information compliant with IPC 608.17.1 ( see notes 12, 13, 14 on plan page A1.0) -IPC 106.3.1 |
||
| 05/08/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |