Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0523-01171
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2023 | Site Engineering | APPROVED | |||
| 05/16/2023 | Site Zoning | APPROVED | |||
| 06/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/14/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0523-01171 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 6/14/2023 1:56:54 AM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/14/2023 1:55:45 AM 1. Add to the list of applicable building codes on sheet A0.0 The City of Tucson/ Pima County Outdoor Lighting Code and ICC A117.1- 2009 Accessible and Usable Buildings and Facilities. 2. Indicate the existing buildings overall height and area in the building code summary on sheet A0.0. 2018 IBC 503 and 504. 3. Indicate on the drawings that Fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. 4. Indicate on the finish schedule that all interior finishes will be in accordance with 2018 IBC 803.1. 5. Indicate if the existing tenant demising wall is a fire rated assembly on the drawings. 2018 IBC 707.3. Note on the drawings that any openings, existing or new within the fire rated barrier will be filled to match or exceed the fire rating of the wall. 2018 IBC 714. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/14/2023 1:56:31 AM 1. Provide a mechanical COMcheck or other approved methodology for the project for the new proposed units that is in compliance with the 2018 IECC. 2. The horizontal refrigerant pipe support detail 5 on sheet M2.1 indicates to refer to structural drawings for method of suspension and attachment however this information was not found on the drawings. Provide information on how this is to be supported. 3. Provide a detail on how the new sheet metal ductwork is to be supported from the existing ceiling. 4. The roof plan on sheet MEP1.1 indicates the center of the new HVAC unit to be 10 ft minimum from the edge of the building. This should be from the edge of the unit to the edge of the roof edge. It is unknow inf the existing building has a parapet that will act as fall protection or if an additional guard will need to be installed. Note how fall protection will be provided and correct the dimensions on the drawing. 2018 IBC 1015.6. Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/14/2023 1:56:08 AM 1. Provide an interior lighting COMcheck or other approved methodology for the project for the new proposed lighting that is in compliance with the 2018 IECC. 2. Indicate on the drawings that all exterior lighting will be in compliance with the Tucson/ Pima county ordinance. 3. The fire alarm control panel is shown located above the desk in the office plan detail 1 and 2 on sheet E3.3. Remove the FACP from the detail or note on the drawings to see the Fire Alarm Plans for the exact mounting location of the panel. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/11/2023 11:02:08 PM First Plumbing Review: 1). one compartment prep sink & mop sink on plan page P1.2 needs to discharge to the existing grease system. -Tucson Plumbing Code Amendments 2). Show mixing valve to be located at lavatory on plan page P1.2 or P2.1 -IPC 419.5 |
||
| 05/08/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |