Permit Number: TC-COM-0426-00626
Parcel: 141011980

Address:
5306 S CIVANO BL

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0426-00626
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2026 Commercial Electrical APPROVED
05/20/2026 Site Zoning APPROVED
05/18/2026 Water - PDSD APPROVED
05/15/2026 Site Engineering NOT REQUIRED
05/20/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/18/2026 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0426-00626
ADDRESS/PARCEL: (5306 S CIVANO BL TUCSON, AZ 85747)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS: With the short period of time we have to review, it is possible that I may have missed relevant information. Please see my comments below and address them with this in mind.
1. SHEET CS.2 BUILDING CODE REVIEW / EGRESS PLAN
a. Smoke Alarm required per IBC 508.5.7. This information can’t be found within the set of drawings. Please address this requirement.
b. Between A-2 and R-3 of 1 hr separation with sprinkler per IBC 508.4. Detail drawing illustrating this code requirement can’t be found within the set of drawings. Please address this requirement.
c. Handicap parking stall location. Please provide a drawings showing the location of the handicap stall as well as the accessible route.
2. SHEET A5.0 ENLARGED RESTROOM PLAN
a. The turning space shall be a circular space with a 67-inch minimum diameter. ICC A117.1 sec 304.3.1.1 (60 inches is shown on the drawing Keynotes). Please correct this item.
3. Please confirm that there is no physical connection between the restaurant and the residence above function wise.
4. Please resubmit.
05/18/2026 Commercial Mechanical REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0426-00626
ADDRESS/PARCEL: 5306 S CIVANO BL TUCSON, AZ 85747

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please provide general room exhaust for appliances that are located in the prep room and do not require a Type II hood (e.g. dishwasher, panini maker). The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.1, exception 6, IMC 2024.
05/18/2026 Commercial Plumbing REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0426-00626
ADDRESS/PARCEL: 5306 S CIVANO BL TUCSON, AZ 85747

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Coffee shops utilize milk and other dairy products, therefore, the 3-compartment sink, hand sink, and service sink are required to discharge through a grease interceptor. This requirement may be appealed to RWRD. Reference: Section 1003.3, IPC 2024, as amended by the City of Tucson.
2. Please verify the sanitary drainage piping materials are rated for the temperature of the waste discharged from the dishwasher in accordance with Section 702.5, IPC 2024.
05/19/2026 Fire New Construction REQUIRES RESUBMIT -Resolve all building comments.
john.vincent@tucsonaz.gov
5203495581
05/04/2026 PDSD Application Completeness Express REVIEW COMPLETED