Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0426-00608
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/08/2026 | Commercial Building | APPROVED | |||
| 05/12/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/06/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0426-00608 (4102 E LINDEN ST TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 2. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. 3. Provide conductor size and type for each new equipment, NEC chapter 3, wiring methods. Include wet location rating. 4. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 5. Show a GFCI and weather protected receptacle outlet on the same level within 25’ of exterior HVAC equipment, [NEC 210.62]. |
||
| 05/12/2026 | Commercial Mechanical | REQUIRES RESUBMIT | Comment not addressed. Provide construction documents sealed by an Arizona Registrant that are complete and clearly indicate the extent of the proposed work. [Initial comment: Provide construction documents sealed by an Arizona Registrant that are complete and clearly indicate the extent of the proposed work (i.e. not just heating/cooling load calculations for an unidentified activity). Reference: Section 107.2.1, IBC 2024.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 04/30/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |