Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0426-00604
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2026 | Site Engineering Standard | APPROVED | |||
| 05/19/2026 | Site Zoning Standard | APPROVED | |||
| 05/18/2026 | Commercial Mechanical Standard | NOT REQUIRED | |||
| 05/11/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 05/18/2026 | Water - PDSD Standard | NOT REQUIRED | |||
| 05/20/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please revise the building code analysis to indicate the total number of stories in the building and identify the story on which this project is located. Section 107.2.1 of the IBC. 2. Please revise the plans to provide a life safety/egress plan. Section 107.2.1 of the IBC. 3. Additionally, indicate the path(s) of exit discharge to a public way or safe dispersal area. Sections 107.2.3 and 1028.5 of the IBC. 4. Please identify which entrances and exits are accessible, provide the required accessibility signage, and indicate the mounting locations and installation details for the signage. Section 1111 of the IBC. 5. Please revise the plans to indicate the heights of the new partition walls and provide either a metal stud table or structural calculations demonstrating that the metal studs used for interior walls and partitions exceeding 6 feet in height, including finish materials, have adequate strength and stiffness to resist applicable loads, but not less than a horizontal load of 5 psf. Section 1607.15 of the IBC. 6. Please provide ceiling heights on the Reflected Ceiling Plan. Section 107.2.1 of the IBC. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 05/11/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0426-00604 (845 N PARK AV Unit:UNIT 155 TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide designated electrical sheets for the electrical work being done. 2. Provide an Electrical floor plan that shows the location of all new, modified and existing electrical work. Mark each electrical device, outlet, light, etc. as existing, new, or relocated. 3. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 4. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. 5. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 6. Provide complete compliance with the 2018 IECC for the interior lighting, including sensors and lighting controls as required. (typically COMcheck.) Additional comments may be forthcoming with complete electrical plans. |
||
| 05/18/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0426-00604 ADDRESS/PARCEL: 845 N PARK AV Unit:UNIT 155 TUCSON, AZ 85719 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Please revise the Building Code Analysis to include the minimum plumbing facilities required by Table 2902.1 and Section 2902.2 of the 2024 IBC for the mercantile occupancy. A service sink and drinking fountain are required. Please show the location of these fixtures on the plans. |
||
| 05/20/2026 | Fire New Construction Standard | REQUIRES RESUBMIT | -Resolve all building comments. john.vincent@tucsonaz.gov 5203495581 |
||
| 04/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |