Permit Number: TC-COM-0426-00596
Parcel: 121120040

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0426-00596
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/23/2026 Commercial Plumbing Express REQUIRES RESUBMIT 1. A 1 inch water meter, which, according to Tucson Water, is capable of supporting a maximum demand of 50 GPM, is currently serving this address. A 1 inch PEX water service pipe is limited to a maximum water velocity of 8 feet per second, or 14.5 GPM. What is the calculated water demand of this building? Reference: Section 107.2.1, IBC 2024.
2. Show the present location of the reduced pressure backflow assembly and the proposed new location of the assembly. Indicate the size of the assembly. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf .

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.