Permit Review Detail
Permit Number: TC-COM-0426-00573
Parcel: 10701030A
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0426-00573
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/01/2026 | Commercial Electrical | APPROVED | |||
| 05/07/2026 | Site Zoning | APPROVED | |||
| 04/24/2026 | Site Engineering | NOT REQUIRED | |||
| 05/08/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/06/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Provide signed and sealed structural calculations prepared by an Arizona-licensed design professional for the design of this project. IBC Section 107.2.7. Please reference 2024 IEBC Chapter 4 if using like for like materials for the repair. 2. Where balconies or other elevated walking surfaces have weather-exposed surfaces and the structural framing is protected by an impervious moisture barrier, the construction documents shall include complete details for all elements of the impervious moisture barrier system, including the manufacturer’s installation instructions. Please revise the plans accordingly. IBC Sections 107.2.5 and 2304.12.2. 3. IBC Section 2304.12.2.5 requires the impervious moisture barrier system protecting structural wood framing to provide positive drainage for moisture that penetrates the moisture-permeable floor topping, such as concrete. Please revise the plans to identify the method used to provide positive drainage. For example, indicate sloped floor framing or an equivalent approved drainage method. 4. IBC Section 2304.12.2.6 requires cross ventilation for enclosed spaces at exterior balconies and elevated walkways exposed to moisture. Openings shall provide a net free cross-ventilation area of not less than 1/150 of the area of each separate space. Please revise the plans to demonstrate compliance. For example, provide soffit venting details and calculations. 5. Additionally please indicate the extent of the repairs to the stairway, if any. IBC 107.2.1 Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson |
||
| 05/08/2026 | Fire New Construction | REQUIRES RESUBMIT | Resolve building review comments. Questions: patricia.shelton@tucsonaz.gov |
||
| 04/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |