Review Details: COMMERCIAL FENCE/WALL v.1
Permit Number - TC-COM-0426-00556
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2026 | Commercial Electrical | APPROVED | |||
| 05/04/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/27/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Pedestrian Gate Accessibility The submitted plans do not provide sufficient information to demonstrate compliance with accessibility requirements for the proposed pedestrian gate. Please revise the plans to address the following in accordance with 2024 IBC Section 1104 and the 2017 ICC A117.1: A. Clear Width (Section 404.2.2) Provide a minimum clear opening width of 32 inches measured between the face of gate and stop, with the door open 90 degrees. B. Maneuvering Clearance (Section 404.2.3.2): Provide a minimum 18-inch maneuvering clearance at the front approach on the pull side of the gate. C. Door and Gate Hardware (Section 404.2.6): Provide details demonstrating that all hardware (handles, pulls, latches, locks, and other operable parts): Are operable with one hand and do not require tight grasping, pinching, or twisting of the wrist. Comply with the following operational force limits: 15 pounds maximum for forward pushing or pulling motion. 28 inch-pounds maximum for rotational motion. D. Hardware Height (Section 404.2.6.1): Provide dimensions indicating that operable hardware is installed not less than 34 inches and not more than 48 inches above the finished floor or ground surface. E. Gate Surface (Section 404.2.9): Provide details showing a smooth surface on the push side of the gate extending the full width within 10 inches of the bottom of the gate to prevent wheelchair footrests from catching. Kick plates or equivalent detailing may be used to demonstrate compliance. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 04/20/2026 | Site Engineering | REQUIRES RESUBMIT | Site Engineering Review TC-COM-0426-00556 1302 W AJO WY Description: Install front gate at Desert Pueblo Mobile Home Park Site Engineering comments are as follows: 1. Fire examiner will be added to the next review cycle. The minimum width for a one-way access lane or PAAL serving as a fire lane is 20 feet per UDC 7.4.6-2. The site plan view of the drive shows minimum 12’-6” clearance. 2. See Building examiner’s comments regarding gate clear space and area for maneuverability. To re-submit, visit the Tucson Development Center Online at: https://tdc-online.tucsonaz.gov/#/home The instructions for resubmittal can be found at: Revisions and Resubmittals Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 04/27/2026 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0426-00556 1302 W. Ajo Wy. Tucson, AZ 85713 Front Gate and Pedestrian Gate (1st Review) TRANSMITTAL DATE: 4/27/2026 This site is located in the MH-1 zone (UDC 4.7.10). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Please dimension the accessible pathway to ensure it maintains a minimum 4’ unobstructed width as noted in Technical Standards 7-01.4.3.A. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11626 2. Comment: Please address Building Examiner’s comment as it relates to pedestrian gate minimum clearance for maneuverability. 3. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 04/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |