Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0426-00556
Parcel: 11918027A

Address:
1302 W AJO WY

Review Status: Requires Resubmit

Review Details: COMMERCIAL FENCE/WALL v.1

Permit Number - TC-COM-0426-00556
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2026 Commercial Electrical APPROVED
05/04/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/27/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Pedestrian Gate Accessibility

The submitted plans do not provide sufficient information to demonstrate compliance with accessibility requirements for the proposed pedestrian gate. Please revise the plans to address the following in accordance with 2024 IBC Section 1104 and the 2017 ICC A117.1:

A. Clear Width (Section 404.2.2)
Provide a minimum clear opening width of 32 inches measured between the face of gate and stop, with the door open 90 degrees.

B. Maneuvering Clearance (Section 404.2.3.2):
Provide a minimum 18-inch maneuvering clearance at the front approach on the pull side of the gate.

C. Door and Gate Hardware (Section 404.2.6):
Provide details demonstrating that all hardware (handles, pulls, latches, locks, and other operable parts):

Are operable with one hand and do not require tight grasping, pinching, or twisting of the wrist.
Comply with the following operational force limits:
15 pounds maximum for forward pushing or pulling motion.
28 inch-pounds maximum for rotational motion.

D. Hardware Height (Section 404.2.6.1):
Provide dimensions indicating that operable hardware is installed not less than 34 inches and not more than 48 inches above the finished floor or ground surface.

E. Gate Surface (Section 404.2.9):
Provide details showing a smooth surface on the push side of the gate extending the full width within 10 inches of the bottom of the gate to prevent wheelchair footrests from catching. Kick plates or equivalent detailing may be used to demonstrate compliance.
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
04/20/2026 Site Engineering REQUIRES RESUBMIT Site Engineering Review

TC-COM-0426-00556
1302 W AJO WY

Description: Install front gate at Desert Pueblo Mobile Home Park

Site Engineering comments are as follows:

1. Fire examiner will be added to the next review cycle. The minimum width for a one-way access lane or PAAL serving as a fire lane is 20 feet per UDC 7.4.6-2. The site plan view of the drive shows minimum 12’-6” clearance.
2. See Building examiner’s comments regarding gate clear space and area for maneuverability.

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

The instructions for resubmittal can be found at: Revisions and Resubmittals

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
04/27/2026 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0426-00556
1302 W. Ajo Wy. Tucson, AZ 85713
Front Gate and Pedestrian Gate (1st Review)

TRANSMITTAL DATE: 4/27/2026

This site is located in the MH-1 zone (UDC 4.7.10).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Please dimension the accessible pathway to ensure it maintains a minimum 4’ unobstructed width as noted in Technical Standards 7-01.4.3.A. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11626
2. Comment: Please address Building Examiner’s comment as it relates to pedestrian gate minimum clearance for maneuverability.
3. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
04/14/2026 PDSD Application Completeness Express REVIEW COMPLETED