Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0426-00553
Parcel: 117120490

Address:
46 W CONGRESS ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0426-00553
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2026 Water - PDSD APPROVED
04/30/2026 Commercial Mechanical NOT REQUIRED
04/30/2026 Commercial Plumbing NOT REQUIRED
04/17/2026 Site Engineering NOT REQUIRED
05/04/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/04/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please provide a demo or existing/ demo plan for this project clearly indicating the existing space to be demoe’d and a description od the work. IBC 107.2.1
2. Please amend the plans to show a demo and new reflected ceiling plan. IBC 107.2.1
3. Please revise the plans to demonstrate that the accessible bar/counter seating complies with the technical provisions of ICC A117.1 (2017). Provide dimensions and details showing a compliant forward approach, including a minimum 30-inch-wide clear floor space, a counter height not exceeding 34 inches, and compliant knee and toe clearances. Knee and toe clearance shall provide a minimum depth of 17 inches for toe clearance with at least 11 inches of that depth providing knee clearance (27 inches minimum height). Indicate these dimensions clearly on the plans.
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
04/29/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0426-00553 (46 W CONGRESS ST TUCSON, AZ 85701)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide an electrical demo plan for the ‘previously existing restaurant’. The service counter, bred warmers and toasters, POS, etc.. were all removed.
2. Provide an updated electrical panel schedule for the ‘previously exiting restaurant’ showing all modified, demo’ed, etc. circuits, NEC 408.4.
05/04/2026 Site Zoning REQUIRES RESUBMIT 1. COMMENT: Parcel lines on site plan are incorrect and currently show they bisect the suites in question. Please correct and resubmit.

On resubmittal, please send an email to the Site Zoning Reviewer, Fernando Garcia, for faster review at fernando.garcia2@tucsonaz.gov.
05/01/2026 Fire New Construction REVIEW COMPLETED
04/17/2026 PDSD Application Completeness Express REVIEW COMPLETED