Review Details: COMMERCIAL FENCE/WALL v.1
Permit Number - TC-COM-0426-00537
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2026 | Design Review | APPROVED | No changes to fence design. Minimal height increase. No impact to facades. | ||
| 04/17/2026 | Site Engineering | APPROVED | |||
| 04/22/2026 | Site Zoning | APPROVED | |||
| 04/27/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/27/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Sheet G-111. Please update the governing codes to use the currently adopted applicable code editions. IBC 107.2.1 https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 2. Provide the signed and sealed structural calculations, prepared by an Arizona licensed registrant, used in the design of this project. IBC 107.2.7 3. Please provide a project specific statement of special inspections for this project, stating requirements for the special inspections and required tests. IBC 107.2.1, IBC 1704, IBC 1705 Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B completed with the next submittal. IBC 107.1 SI form link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf 4. Pedestrian Gate – Accessibility Requirements Please revise the plans to include the following accessibility provisions for the pedestrian gate in accordance with the 2017 ICC A117.1: A. Maneuvering Clearance (Section 404.2.3.2) Provide a minimum 18-inch maneuvering clearance on the front approach, pull side of the gate. B. Door and Gate Hardware (Section 404.2.6) Revise details to demonstrate that all hardware (handles, pulls, latches, locks, and other operable parts): Is operable with one hand and does not require tight grasping, pinching, or twisting of the wrist. Meets the following force limitations: 15 pounds maximum for hardware operated by a forward pushing or pulling motion. 28 inch-pounds maximum for hardware operated by rotational motion. C. Hardware Height (Section 404.2.6.1) Provide dimensions showing that operable hardware is mounted not less than 34 inches and not more than 48 inches above the finished floor or ground surface. D. Gate Surface (Smooth Surface Requirement) (Section 404.2.9) Provide details showing a smooth surface on the push side of the gate extending the full width, located within 10 inches of the bottom of the gate, to prevent wheelchair footrests from catching. Kick plates or equivalent detailing may be used to demonstrate compliance. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 04/13/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |