Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-0426-00529
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/13/2026 | Commercial Electrical Express | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0426-00529 (3860 E PIMA ST TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Incomplete Submittal – Please include a detailed construction plan along with any product specs that may be necessary to provide a commercial plan review. Provide an electrical plan showing any/all electrical work. Plans shall include (as necessary for scope of work), but may not be limited to items below: 2. Electrical demo plans. 3. Electrical floor plan that shows the location of all new or modified electrical work. 4. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 5. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders for lights that were added. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 6. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. 7. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 8. Show any lighting fixtures being added for both interior and exterior egress and exit lights. Additional comments may be forthcoming with complete electrical plans. |
||
| 04/13/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |