Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0426-00462
Parcel: 11707216A

Address:
711 S 6TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.2

Permit Number - TC-COM-0426-00462
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2026 Commercial Mechanical APPROVED
06/11/2026 Commercial Plumbing APPROVED
06/11/2026 Water - PDSD APPROVED
06/15/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/05/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email Mark.Masek@tucsonaz.gov
2nd Review – New Comments
5. Sheet A.1
Original Comment:
Please amend the site plan to provide dimensioned distances between the building and the property line. IBC 107.2.1.
New Comment (2nd Review):
Please revise the site plan to clearly indicate the actual distance from the building to the property line. If the fire separation distance (FSD) is less than 10 feet, the exterior wall openings shall comply with the maximum allowable opening limitations of 2024 IBC Table 705.8 (formerly Table 705.8/705.9, as applicable). The exterior door at the Storage/Receiving area appears to exceed the permitted opening allowance. Please relocate the door or otherwise revise the design to demonstrate compliance.
6. Sheet A.1
Original Comment:
Please verify that the fire-resistance ratings of all exterior walls are shown and comply with IBC Table 705.5. For example, the Storage/Receiving room appears to be located less than 10 feet from the property line.
New Comment (2nd Review):
Please revise the plans to identify the approved listed fire-resistance-rated assembly details for all rated walls, floors, and ceilings. Provide the applicable listing numbers (UL, GA, or approved equivalent) and corresponding assembly details directly on the construction documents. This information is required to verify compliance with the required fire-resistance ratings. 2024 IBC Sections 107.2.1 and 703.2.
7. Sheet A.1
Original Comment:
Please revise the occupant load calculations to clearly show the total design occupant load for the building.
New Comment (2nd Review):
Please provide a complete occupant load calculation for the entire building, including both the existing building area and the proposed addition. The total design occupant load is required for issuance of the updated Certificate of Occupancy. Provide the area, occupant load factor, and calculated occupant load for each space, along with the overall building occupant load. IBC 107.2.1.
12. Architectural Drawings Required
IBC 107.2.1
B. Original Comment:
Provide fire-resistance-rated parapets where required, including where rated exterior walls are provided. IBC 705.11.
New Comment (2nd Review):
A parapet is required at the new Storage/Receiving area. Please revise the construction documents to provide parapet details and demonstrate compliance with 2024 IBC Section 705.11.
L. Original Comment:
EIFS systems shall identify the evaluation report number and provide a copy of the report. IBC 1407.2.
New Comment (2nd Review):
The exterior finish is identified on the construction documents as “Synthetic Stucco.” Please provide the applicable ICC-ES Evaluation Report (ESR) number, or an approved equivalent evaluation report, and submit a copy for review. Additionally, if the evaluation report requires special inspections for installation, please identify those requirements on the construction documents and include them in the special inspection program.
9. Accessible Toilet Room
Original Comment:
Please amend the plans to provide interior elevations of the new toilet room showing details, dimensions, and mounting heights for the following:
A. Lavatory height, knee clearance, toe clearance, and pipe protection. 2017 ICC A117.1 Sections 306 and 606.
B. Water closet and toilet compartment requirements. 2017 ICC A117.1 Section 604.
New Comment (2nd Review):
Please revise the layout of the new toilet room to comply with the turning space requirements of the 2017 ICC A117.1. As this is new construction, a complaint-turning space must be provided in accordance with Section 304. The turning space shown does not appear to meet the required dimensions. Please revise the design and provide dimensions demonstrating compliance.

Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
06/02/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0426-00462 (711 S 6TH AV TUCSON, AZ 85701)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide the conductor sizing and wiring method, from the Service Entrance panel to the new panel ‘B’, NEC 215.2. Show Overcurrent Protection, NEC 215.3.
2. Provide Fault Current Analysis and show new equipment/panels (Panel ‘B’) AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2023 NEC 110.24.
3. Show new Panel’s and other new equipment (Panel ‘B’) with AIC ratings greater than or equal to the Available Fault Currents calculated, 2023 NEC 110.10.
4. Show equipment grounding conductors for each new circuit sized per NEC 250.122(A), and Table 250.122. Multiple equipment grounding conductors are undersized in panel ‘B’.
06/10/2026 Fire New Construction REQUIRES RESUBMIT Resolve all building comments. Indicate whether or not the building has a fire alarm.
Questions: patricia.shelton@tucsonaz.gov
06/15/2026 Historic REQUIRES RESUBMIT Your proposed project was reviewed by Historic Preservation staff, West University Historic Zone Advisory Board (WUHZAB), and the Tucson Pima County Historical Commission, Plans Review Subcommittee (PRS). There are several conditions of approval that must be addressed before your application can proceed. Please revise your Design Package as follows and resubmit:
(1) Double hung windows with wood frame (can be metal clad wood windows)
(2) Front door to be will be 2-panel
(3) Distinguish the stucco from the contributing properties on site (key noted, clouding etc) on the plans
Please resubmit a final revised Design Package to show that the noted conditions are being met. Resubmit under the SD#, a single compressed pdf package.
Once reviewed and deemed completed by staff, a final historic Decision Notice will be generated and signed by PDSD Director. The plans will be signed by staff and you may proceed to permitting
Questions: Contact Michael.Taku@tucsonaz.gov
06/02/2026 Site Engineering REQUIRES RESUBMIT Permit Activity Number: TC-COM-0426-00462 (1st Review)
Project: Add a workroom, office and storage/receiving area.
Location: 711 S 6TH AV
Review Date: 6/2/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov

Site Engineering Comments:
1. Site Engineering has completed its review of the submitted plan set. However, Site Engineering is unable to grant final approval for Commercial Permit TC-COM-0426-00462 until the associated Development Package has been submitted and has received full approval and has been issued. Please resubmit for final approval once the development package has been approved and issued by all applicable reviewers.
06/11/2026 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0426-00462
711 S. 6th Ave. Tucson, AZ 85701
New Work Room, Office, and Storage/Receiving Area (2nd Review)

TRANSMITTAL DATE: 6/11/2026

The site is located in HC-3 zone (UDC 4.7.22).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Previous comment 1 not addressed: Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the minimum requirements is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/submittal_requirements.pdf. Site zoning is unable to approve this building permit until the DP has been approved by all reviewers.
2. Comment: Previous comment 2 not addressed: This site is located within Armory Park Historic Preservation Zone. Historic review and approval is also required prior to site zoning approval.
3. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
06/01/2026 PDSD Application Completeness Express REVIEW COMPLETED