Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0426-00457
Parcel: 12620001C

Address:
800 S CONCERT PL

Review Status: Requires Resubmit

Review Details: HAST - COMMERCIAL NEW ADD/ALT FAST TRACK v.1

Permit Number - TC-COM-0426-00457
Review Name: HAST - COMMERCIAL NEW ADD/ALT FAST TRACK v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2026 Commercial Electrical APPROVED
04/16/2026 Commercial Mechanical APPROVED
04/16/2026 Commercial Plumbing APPROVED
04/16/2026 Water - PDSD APPROVED
04/28/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/17/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please provide a project specific statement of special inspections for this project, stating requirements for the special inspections and required tests. IBC 107.2.1, IBC 1704, IBC 1705
Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B
completed with the next submittal. IBC 107.1 SI form link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf
2. Please provide the soils report by Atek ENGINEERING; JOB NO. 250277-1, used in the design of this project. IBC 107.2.1
3. Please include all the sheets listed in the sheet index. IBC 107.2.1 For example, g1.2 is listed in the sheet index but was not included in the construction drawings.
4. Please provide a list of architectural special inspections. For example, EIFS and also Liquid applied water resistive barriers, if used. IBC 1705.17 & IBC 1705.17.1
5. Please clarify the plumbing fixture count. The plans appear to indicate three (3) water closets for Men and three (3) for Women; however, an additional six (6) unisex water closets are also listed following the Men’s and Women’s fixture counts. Please confirm whether these unisex fixtures are in addition to the Men’s and Women’s totals or if they are intended to be included within the overall fixture count.
Provide a revised plumbing fixture calculation that clearly identifies the total number of required and provided fixtures. IBC 107.2.1. Additionally please provide the appropriate signage if using UNI-SEX

6. Sheet a9.1: Please indicate the density (PSI) of the tapered insulation used under the TPO
7.. Please provide the approval agency reports/ICC ESR numbers for the EIFS system, and Liquid applied barrier if used. IBC 107.2.1

Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
04/23/2026 Fire New Construction REQUIRES RESUBMIT Please resolve building review comments.
Questions: patricia.shelton@tucsonaz.gov
04/17/2026 Outdoor Lighting REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. The addition of the unshielded stage lighting must be approved through an appeal to the building official. The outdoor lighting code does not address this lighting condition and thus a code analysis and justification must be provided, by the EOR, to the building official for review and approval through an appeal.
2. Reference sheet e5.0, City of Tucson Outdoor Lighting Code Calculations table. The provided lumen limits under part A of this section are incorrect. Per OLC Table 401.1, the maximum per acre is 175,000 shielded and 11,000 unshielded. Please clarify how your numbers were produced and correct the calculations.
3. As part of your site lighting plan, please clearly delineate the 6 acres of developed area you are declaring for this lighting use.
a. Because Reid Park is fully developed, please provide a declaration that the 6 acres being claimed as part of this development, are not also being claimed under any other projects or developments.
4. An Outdoor Lighting Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf
04/28/2026 Site Engineering REQUIRES RESUBMIT Due to the extensive site work being proposed with this permit, a Development Package must be submitted and approved prior to Engineering approval of TC-COM-0426-00457.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
04/27/2026 Site Zoning REQUIRES RESUBMIT Due to the extensive site work being proposed with this permit, a Development Package must be submitted and approved prior to zoning approval of TC-COM-0426-00457
04/17/2026 Historic REVIEW COMPLETED Review complete. Applicant has gone through review from HLS and PRS and incorporated input recieved.
04/09/2026 PDSD Application Completeness Express REVIEW COMPLETED