Permit Number: TC-COM-0426-00454
Parcel: 12620001C

Address:
800 S CONCERT PL

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0426-00454
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2026 Commercial Electrical Standard APPROVED
04/15/2026 Commercial Mechanical Standard APPROVED
04/15/2026 Commercial Plumbing Standard APPROVED
04/15/2026 Water - PDSD Standard APPROVED
04/16/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/16/2026 Commercial Building Standard REQUIRES RESUBMIT
04/16/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TC-COM-0426-00454 (800 S CONCERT PL TUCSON, AZ 85716)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. The addition of the unshielded stage lighting must be approved through an appeal to the building official. The outdoor lighting code does not address this lighting condition and thus a code analysis and justification must be provided, by the EOR, to the building official for review and approval through an appeal. After the appeal to the building official, resubmit updated calculations with the stage lighting removed or exempted per the building official decision.
2. Reference sheet e5.0, City of Tucson Outdoor Lighting Code Calculations table. The provided lumen limits under part A of this section are incorrect. Per OLC Table 401.1, the maximum per acre is 175,000 shielded and 11,000 unshielded. Please clarify how your numbers were produced and correct the calculations.
3. As part of your site lighting plan, please clearly delineate the 6 acres of developed area you are declaring for this lighting use.
a. Because Reid Park is fully developed, please provide a declaration that the 6 acres being claimed as part of this development, are not also being claimed under any other projects or developments.
04/07/2026 PDSD Application Completeness Express REVIEW COMPLETED