Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0425-00867
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/16/2025 | Site Engineering | NOT REQUIRED | |||
| 05/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/16/2025 | Commercial Building | REQUIRES RESUBMIT | May 7, 2025 1st Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Sheet G1 1. Please revise the occupant load factor of 100 to 150. The occupant load factor for business occupancies is 150. [Ref. IBC 2018 Sec. 1004.5] 2. The ‘General Building Summary’ on this sheet indicates the Occupancy Group as a Group C. The IBC does not include a Group C occupancy. Please revise this to a Group B occupancy to correlate with the occupancy group indicated with Note 3 on this sheet. [Ref. IBC 2018 Sec. 304.1] 3. The occupant load of 37 indicated on the plumbing calculations conflicts the occupant load indicated with Note 3A on this sheet. Please revise this to correlate with the occupant load and revise the code edition indicated on the plumbing calculations to the 2018 IBC. STRUCTURAL COMMENTS General 1. Please provide an engineer’s structural analysis of the existing roof with the proposed 705lb roof top units indicating what structural modifications are required to support the new units, if any. [Ref. IEBC 2018 Sec. 303.1] MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 05/16/2025 | Commercial Electrical | REQUIRES RESUBMIT | May 7, 2025 1st Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Sheet G1 1. Please revise the occupant load factor of 100 to 150. The occupant load factor for business occupancies is 150. [Ref. IBC 2018 Sec. 1004.5] 2. The ‘General Building Summary’ on this sheet indicates the Occupancy Group as a Group C. The IBC does not include a Group C occupancy. Please revise this to a Group B occupancy to correlate with the occupancy group indicated with Note 3 on this sheet. [Ref. IBC 2018 Sec. 304.1] 3. The occupant load of 37 indicated on the plumbing calculations conflicts the occupant load indicated with Note 3A on this sheet. Please revise this to correlate with the occupant load and revise the code edition indicated on the plumbing calculations to the 2018 IBC. STRUCTURAL COMMENTS General 1. Please provide an engineer’s structural analysis of the existing roof with the proposed 705lb roof top units indicating what structural modifications are required to support the new units, if any. [Ref. IEBC 2018 Sec. 303.1] MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 05/16/2025 | Commercial Mechanical | REQUIRES RESUBMIT | May 7, 2025 1st Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Sheet G1 1. Please revise the occupant load factor of 100 to 150. The occupant load factor for business occupancies is 150. [Ref. IBC 2018 Sec. 1004.5] 2. The ‘General Building Summary’ on this sheet indicates the Occupancy Group as a Group C. The IBC does not include a Group C occupancy. Please revise this to a Group B occupancy to correlate with the occupancy group indicated with Note 3 on this sheet. [Ref. IBC 2018 Sec. 304.1] 3. The occupant load of 37 indicated on the plumbing calculations conflicts the occupant load indicated with Note 3A on this sheet. Please revise this to correlate with the occupant load and revise the code edition indicated on the plumbing calculations to the 2018 IBC. STRUCTURAL COMMENTS General 1. Please provide an engineer’s structural analysis of the existing roof with the proposed 705lb roof top units indicating what structural modifications are required to support the new units, if any. [Ref. IEBC 2018 Sec. 303.1] MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 05/16/2025 | Commercial Plumbing | REQUIRES RESUBMIT | May 7, 2025 1st Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Sheet G1 1. Please revise the occupant load factor of 100 to 150. The occupant load factor for business occupancies is 150. [Ref. IBC 2018 Sec. 1004.5] 2. The ‘General Building Summary’ on this sheet indicates the Occupancy Group as a Group C. The IBC does not include a Group C occupancy. Please revise this to a Group B occupancy to correlate with the occupancy group indicated with Note 3 on this sheet. [Ref. IBC 2018 Sec. 304.1] 3. The occupant load of 37 indicated on the plumbing calculations conflicts the occupant load indicated with Note 3A on this sheet. Please revise this to correlate with the occupant load and revise the code edition indicated on the plumbing calculations to the 2018 IBC. STRUCTURAL COMMENTS General 1. Please provide an engineer’s structural analysis of the existing roof with the proposed 705lb roof top units indicating what structural modifications are required to support the new units, if any. [Ref. IEBC 2018 Sec. 303.1] MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 05/08/2025 | Outdoor Lighting | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0425-00867 ADDRESS/PARCEL: (2504 E LEE ST TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Please provide the spec sheets for all full cutoff light fixtures. Please provide photometric data as well (OLC 104.2) a. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3). 2. Please resubmit |
||
| 05/21/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0425-00867 2504 E LEE ST. - C-1 TI Animal Services (1st Review) TRANSMITTAL DATE: May 21, 2025 Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). Animal Services is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.D.1, .2, .3, & .4 and 4.9.13.O or 4.9.4.D.7 & 4.9.4.D.10-.15. 1. Clearly demonstrate that Use Specific Standards 4.9.4.D.1, .2, .3, & .4 and 4.9.13.O or 4.9.4.D.7 & 4.9.4.D.10-.15 are met. 2. Provide documentation that this site was an approved commercial use, i.e. approved site plan or C of O as it appears that the prior use was multifamily. A development package meeting the requirements of AM 2-06 maybe required. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/13/2025 | Fire New Construction | REVIEW COMPLETED | Fire extinguishers shall comply with section 906 of the 2018 IFC | ||
| 05/02/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 05/16/2025 | Water - PDSD | REVIEW COMPLETED |