Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0425-00867
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2025 | Site Zoning | APPROVED | |||
| 08/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/20/2025 | Commercial Building | REQUIRES RESUBMIT | August 20, 2025 3rd Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Addressed. 2. New Comment: The latest submittal is missing the structural calculations for the masonry wall in-fill and lintel designs. Please ensure this is reuploaded in the next submittal. Sheet G1 1. Addressed. 2. Addressed. 3. Addressed. STRUCTURAL COMMENTS General 1. Addressed. 2. New Comment: The design of the reinforcement needed for the mechanical units included in the structural calculations provided with this submittal must be incorporated into the plan-set and not just included within the calculations. Please incorporate the new structural reinforcement design into the construction drawings. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 08/20/2025 | Commercial Electrical | REQUIRES RESUBMIT | August 20, 2025 3rd Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Addressed. 2. New Comment: The latest submittal is missing the structural calculations for the masonry wall in-fill and lintel designs. Please ensure this is reuploaded in the next submittal. Sheet G1 1. Addressed. 2. Addressed. 3. Addressed. STRUCTURAL COMMENTS General 1. Addressed. 2. New Comment: The design of the reinforcement needed for the mechanical units included in the structural calculations provided with this submittal must be incorporated into the plan-set and not just included within the calculations. Please incorporate the new structural reinforcement design into the construction drawings. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 08/20/2025 | Commercial Mechanical | REQUIRES RESUBMIT | August 20, 2025 3rd Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Addressed. 2. New Comment: The latest submittal is missing the structural calculations for the masonry wall in-fill and lintel designs. Please ensure this is reuploaded in the next submittal. Sheet G1 1. Addressed. 2. Addressed. 3. Addressed. STRUCTURAL COMMENTS General 1. Addressed. 2. New Comment: The design of the reinforcement needed for the mechanical units included in the structural calculations provided with this submittal must be incorporated into the plan-set and not just included within the calculations. Please incorporate the new structural reinforcement design into the construction drawings. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 08/20/2025 | Commercial Plumbing | REQUIRES RESUBMIT | August 20, 2025 3rd Review Dham Developers, LLC. Attn: Clelia Dajlala 742 W. Grant Road Unit 207 Tucson, Arizona 85705 Re: PET GROOMING STORE TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0425-00867 Stantec Project Number: 185215066 Stantec File Number: TUC-25-050 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 2,017 21 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Addressed. 2. New Comment: The latest submittal is missing the structural calculations for the masonry wall in-fill and lintel designs. Please ensure this is reuploaded in the next submittal. Sheet G1 1. Addressed. 2. Addressed. 3. Addressed. STRUCTURAL COMMENTS General 1. Addressed. 2. New Comment: The design of the reinforcement needed for the mechanical units included in the structural calculations provided with this submittal must be incorporated into the plan-set and not just included within the calculations. Please incorporate the new structural reinforcement design into the construction drawings. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 08/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |