Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0425-00849
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2025 | Commercial Plumbing | APPROVED | |||
| 05/13/2025 | Commercial Building | NOT REQUIRED | |||
| 05/19/2025 | Commercial Mechanical | NOT REQUIRED | |||
| 05/22/2025 | Site Zoning | NOT REQUIRED | |||
| 05/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/19/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0425-00849 (2710 N CASTRO AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provided plans must include all required repair work and other unpermitted work noted in the code violation Case: CE-VIO0325-01040. ‘No proper sewage hookup, only able to run electrical on one plug, water to Unit is ran from water hoes’ 3. Provide an electrical plan showing any/all electrical work. Include an electrical floor plan showing the location of all new electrical work. Plans shall include, but may not be limited to items below: 4. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 5. Provide new and updated panel schedules, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 6. Designate the circuit number, that corresponds to the panel schedule, at the location of each new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 05/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |