Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0425-00795
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/27/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please address comment 4 d. since you are keeping the doors. c. Please tell us what you are going to do with those two existing doors and that short interior wall. - Doors are being kept. No changes to the doors for this project. d. Should both door be kept, ensure that the required accessible space between doors are met per ICC A117.1 figure 404.2.5 drawing configuration b. A distance of Swinging doors in series when placed too closely together can create a condition where a person using a wheelchair may pass through one door, and still have to hold that door open while trying to open the second door. To resolve this condition, a minimum distance of 48 inches is required between the doors if the doors swing away from each other or 48 inches plus the width of any door swinging into the space is required [see Figure 404.2.5 and Commentary Figure C404.2.5(a)]. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/31/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-COM-0425-00795 Location: 2474 E RIVER RD Review Date: 10/31/2025 Site Engineering Comments: 1. The proposed enclosure of a patio is an expansion of gross floor area and requires a Development Package. Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. 2. Site Engineering is unable to review and approve permit TC-COM-0425-00795 until the associated Development Package is reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/29/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-COM-0425-00795 2474 E. River Rd. Tucson, AZ 85718 Enclose back patio under existing roof (2nd Review) TRANSMITTAL DATE: 10/29/2025 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.15). Administrative and Professional Office is an allowed use in the zone subject to Use Specific Standard 4.9.13.K. 1. Comment: Previous comment 1 not addressed. The proposed enclosure of a patio is an expansion of gross floor area and requires a Development Package. Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. Site zoning is unable to approve this building permit until the DP has been approved by all reviewers. 2. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 10/13/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |