Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0425-00746
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2025 | Commercial Electrical Standard | APPROVED | |||
| 05/08/2025 | Site Engineering Standard | APPROVED | |||
| 04/29/2025 | Site Zoning Standard | APPROVED | |||
| 05/08/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/07/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0425-00746 ADDRESS/PARCEL: (1050 N MOUNTAIN AV TUCSON, AZ 85719) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. LAVATORIES a. Lavatories & water closets shall be handicapped accessible, ICC A117.1 & IBC 2902 compliant. Lavatory shall be maximum 34 inches above floor to the higher of the rim or counter surface, faucets and soap dispenser shall have a reach depth of 11 inches per ICC A117.1 section 606. New or replacement lavatory faucet operator shall also be metered & shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.11 & 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Provide tempered water for the lavatory using an approved device conforming to ASSE 1070. Reference: Sections 419.5 and 607.1.2, IPC 2018. Water supply and drain pipes under lavatories shall be insulated to protect against contact per ANSI 606.6 complying to clearances shown on Figure 606.3 ICC A117.1 2. WATER CLOSET a. At water closet, show the 60" W x 56" D clearance area on the floor per ANSI A117 Figure 604.3 Ensure no other fixtures are within this area. 3. GRAB BARS a. Grab bars ICC ANSI A117.1 section 604.5, toilet and bathing facilities, grab bars and shower seat reinforcement sec 1104.11 ICC A117.1, Kitchens sec 1104.12 ICC A117.1Sheet A0 Code Analysis 4. ACCESSIBILITY UPGRADES a. Requires that accessibility be provided. Accessibility upgrades shall be required in accordance with IEBC.305.7. Accessibility upgrades equaling 20% of the cost of the project shall be made. For example, the Bathroom is not compliant. 5. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 05/07/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Provide tempered water for the lavatories in restrooms using approved devices conforming to ASSE 1070. Reference: Sections 419.5 and 607.1.2, IPC 2018. 2. Provide shower valves that comply with the requirements of Section 412.3, IPC 2018. |
||
| 04/30/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 04/16/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |