Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0425-00727
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/30/2025 | Site Zoning | APPROVED | |||
| 06/04/2025 | Site Engineering | NOT REQUIRED | |||
| 06/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/30/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0425-00727 ADDRESS/PARCEL: (7650 E BROADWAY BL Unit:UNIT 203 TUCSON, AZ 85710) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. Plumbing Fixture Calculation: a. The table indicates 2 lavs each for men and women. i. Actual count shown on the plan is 1 for each men and women. ii. Please correct your table information. b. The ADA Restroom: i. Clearly label the location of this accessible restroom. ii. Provide an enlarged floor plan and ensure to show the floor clearances. Ensure that the lav is not within the clear floor area for the water closet complying to ICC A117.1. c. Drinking Fountain i. Locate and label the location of the drinking fountain. ii. Show the distance from the Professional Services Office to the service sink. d. Service Sink i. Project Narrative mentions mop sink. 1. The floor plan does not show it. 2. The Partial Plumbing Water Floor Plan shows an S-1 sink exist. ii. Locate and label the location of the service sink on the plans. iii. Show the distance from the Professional Services Office to the service sink if location is outside the office. 2. Sink shall be maximum 34 inches above floor to the higher of the rim or counter surface, faucets and soap dispenser shall have a reach depth of 11 inches per ANSI 606.5 a. Water supply and drain pipes under lavatories shall be insulated to protect against contact per ANSI 606.6 3. CODE ANALYSIS a. Within the Code Analysis, include the actual calculation of the occupant load. i. Calculate space by space by showing the name of the space, the area, the occupant load factor and the number of occupant(s). No rounding up allowed on these rows. ii. At the bottom indicate the total. 1. Only round up can be done at the final total line. 4. Proposed Use a. The city understands that you are proposing B Occupancy. b. Do you concur entering in the Certificate of Occupancy document as Professional Services Office as indicated in IBC 304.1 Business Group B Occupancy Classification. i. If you concur, please add this “Professional Services Office” within your Code Tabulations in your sheet A101. 5. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 05/28/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Clarify the connection to the existing building drain system. The fixture drain serving an automatic clothes washer shall connect to a fixture branch that is at least 3 inches in diameter. Reference: Section 406.2, IPC 2018. 2. Provide an approved vacuum relief valve for the scheduled bottom-fed water heater that is located above the fixture outlets. Reference: Section 504.2, IPC 2018. 3. If the specified water heater is not supplied with integral heat traps, provide heat traps on the supply and discharge piping. Provide insulation per Table C403.11.3, IECC 2018 on the first 8 feet of supply and discharge piping. Reference: Section C404.4, IECC 2018. 4. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves. Reference: Section 604.9, IPC 2018. |
||
| 05/27/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 05/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |