Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0425-00710
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/05/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Coordinate the plumbing drawings with the new plumbing fixtures and references to the fixture schedule that are shown on sheet A1.1but not shown on the plumbing drawings. [Second comment: The City of Tucson drinking fountain policy allows a listed and labeled water dispenser connected to the potable water distribution system to be used in lieu of the required drinking fountains. A water dispenser that is not connected to the potable water distribution system may be substituted for not more than 50% of the required drinking fountains. Reference: Sections 410.3 and 410.4, IPC 2018.] [Initial comment: Clarify how the “water filler” located at the existing sink serves as a point of use water dispenser. The use of a point-of-use water dispenser in lieu of a drinking fountain requires the installation of a listed and labeled dispenser along with a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34” and 48” above the finished floor. See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf] | ||
| 07/30/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |