Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2025 Commercial Electrical Standard APPROVED
07/28/2025 Commercial Mechanical Standard APPROVED
07/25/2025 Site Zoning Standard APPROVED
07/08/2025 Outdoor Lighting Standard NOT REQUIRED Modifications to the outdoor lighting was removed from the scope of work.
07/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/28/2025 Commercial Plumbing Standard REQUIRES RESUBMIT The City of Tucson drinking fountain policy allows a listed and labeled water dispenser connected to the potable water distribution system to be used in lieu of the required drinking fountains. A water dispenser that is not connected to the potable water distribution system may be substituted for not more than 50% of the required drinking fountains. Reference: Sections 410.3 and 410.4, IPC 2018. [Initial comment: Clarify how the “water filler” located at the existing sink serves as a point of use water dispenser. The use of a point-of-use water dispenser in lieu of a drinking fountain requires the installation of a listed and labeled dispenser along with a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34” and 48” above the finished floor. See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf ]
07/03/2025 PDSD Application Completeness Express REVIEW COMPLETED