Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL FENCE/WALL v.1
Permit Number - TC-COM-0425-00690
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/06/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0425-00690 ADDRESS/PARCEL: (423 N TUCSON BL TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. WALL HEIGHT a. There is an issue with the proposed wall height. b. Please see comments from Site Engineering. c. Please see comments from Site Zoning. d. Please resolve and resubmit. 2. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 05/06/2025 | Site Engineering | REQUIRES RESUBMIT | TC-COM-0425-00690 423 N TUCSON BL Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans. Chris Arrington chris.arrington@tucsonaz.gov |
||
| 05/06/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0425-00690 423 N TUCSON BL. - C-1 10’ H Site Wall (1st Review) TRANSMITTAL DATE: May 6, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). Use unknown 1. As site work is proposed per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. 2. Per UDC Article 6.6.2.I the maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; 3. A greater height is required through the rezoning process or the special exception land use process; or, 4. A greater height is required by a specific UDC standard. Either demonstrate that one of the 4 exceptions is met or a Design Development Option (DDO) for wall height will need to be submitted with the required DP to allow the 10’-0” wall within the perimeter yard along the south and west property line. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/22/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |