Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: TC-COM-0425-00688
Parcel: 12110005D

Address:
4766 E GRANT RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0425-00688
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/05/2025 Commercial Electrical Standard APPROVED Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved
Reason:
Date Completed : 4/30/2025 2:16:08 PM
05/05/2025 Commercial Mechanical Standard APPROVED Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 5/5/2025 12:33:21 PM
05/05/2025 Commercial Plumbing Standard APPROVED Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved
Reason:
Date Completed : 5/4/2025 8:06:28 PM
FIRST PLUMBING REVIEW -OK
05/13/2025 Water - PDSD Standard APPROVED
05/13/2025 Site Engineering Standard NOT REQUIRED
05/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/05/2025 Commercial Building Standard REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Denied
Reason:
Date Completed : 5/1/2025 10:44:48 AM
1. General / Updates: For project updates, please submit sheets with all changes clearly marked in revision clouds.
Please provide a written response to each comment; updates without a clear response may not be reviewed. If you
have any questions regarding the comments, you may contact me directly. Updates may result in additional
comments.
2. Sheet S1.1 / Statement of Special Inspections: The list of special inspections provided on Sheet S1.1 appears
incomplete. Due to the scope of work, special inspections for structural steel, field welding, and expansion / adhesive
anchors into concrete will be required. Please revise Sheet S1.1 and resubmit.
3. General / Special Inspection Certificate: Please have the Registered Design Professional in Responsible Charge of
this project complete and return the City of Tucson Special Inspections Certificate with signatures. The form can be
downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf
4. Sheet S1.3 / General Notes & Concrete Notes / Current Code: The currently adopted building code for the City of
Tucson is the 2018 International Building Code and its auxiliary codes. Please review the general notes on Sheet
S1.3 (General Note #1, Concrete Note #1) and revise to remove references to the California Building Code and refer
to the currently adopted ACI codes (ie. ACI 318-14).
5. Sheet S1.3 (2) / Connection Schedule / Missing Detail: The Connection Schedule on Sheet S1.3 appears to be
referencing a shear connection detail that has not been provided. Please confirm what Dimensions A thru D are
referring to and provide a detail if required.
6. Sheet S3.1 / Missing Details: The Roof Framing Plans 1 & 2 on Sheet S3.1 include multiple detail references that do
not appear to be included in the provided construction documents. Refer to Sheet S3.1 for references to Detail 1, 6, 8,
9 and 10/S1.2. Detail 8/S1.2 should include information on connections of EHS cables. Details 9 & 10 should include
information on the connection of new stub columns to the existing roof framing.


Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 5/1/2025 10:01:49 AM
05/13/2025 Site Zoning Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-COM-0425-00688
4766 E GRANT RD. - C-1
Food and Beverage Sales: (1st Review)

TRANSMITTAL DATE: ‎May 13, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the C-1 zone (UDC 4.7.20). Food and Beverage Sales: Excluding Large Retail Establishment is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standard 4.9.13.O.

1. The proposed exterior work requires a development package. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
05/05/2025 Fire New Construction Standard REVIEW COMPLETED Alterations to the fire alarm or fire sprinklers requires a separate permit and submittal.
CO2 Systems requires a separate Operational Plan.
04/22/2025 PDSD Application Completeness Express REVIEW COMPLETED