Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0425-00688
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2025 | Commercial Electrical Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 4/30/2025 2:16:08 PM |
||
| 05/05/2025 | Commercial Mechanical Standard | APPROVED | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 5/5/2025 12:33:21 PM |
||
| 05/05/2025 | Commercial Plumbing Standard | APPROVED | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 5/4/2025 8:06:28 PM FIRST PLUMBING REVIEW -OK |
||
| 05/13/2025 | Water - PDSD Standard | APPROVED | |||
| 05/13/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 05/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/05/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 5/1/2025 10:44:48 AM 1. General / Updates: For project updates, please submit sheets with all changes clearly marked in revision clouds. Please provide a written response to each comment; updates without a clear response may not be reviewed. If you have any questions regarding the comments, you may contact me directly. Updates may result in additional comments. 2. Sheet S1.1 / Statement of Special Inspections: The list of special inspections provided on Sheet S1.1 appears incomplete. Due to the scope of work, special inspections for structural steel, field welding, and expansion / adhesive anchors into concrete will be required. Please revise Sheet S1.1 and resubmit. 3. General / Special Inspection Certificate: Please have the Registered Design Professional in Responsible Charge of this project complete and return the City of Tucson Special Inspections Certificate with signatures. The form can be downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf 4. Sheet S1.3 / General Notes & Concrete Notes / Current Code: The currently adopted building code for the City of Tucson is the 2018 International Building Code and its auxiliary codes. Please review the general notes on Sheet S1.3 (General Note #1, Concrete Note #1) and revise to remove references to the California Building Code and refer to the currently adopted ACI codes (ie. ACI 318-14). 5. Sheet S1.3 (2) / Connection Schedule / Missing Detail: The Connection Schedule on Sheet S1.3 appears to be referencing a shear connection detail that has not been provided. Please confirm what Dimensions A thru D are referring to and provide a detail if required. 6. Sheet S3.1 / Missing Details: The Roof Framing Plans 1 & 2 on Sheet S3.1 include multiple detail references that do not appear to be included in the provided construction documents. Refer to Sheet S3.1 for references to Detail 1, 6, 8, 9 and 10/S1.2. Detail 8/S1.2 should include information on connections of EHS cables. Details 9 & 10 should include information on the connection of new stub columns to the existing roof framing. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 5/1/2025 10:01:49 AM |
||
| 05/13/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0425-00688 4766 E GRANT RD. - C-1 Food and Beverage Sales: (1st Review) TRANSMITTAL DATE: May 13, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). Food and Beverage Sales: Excluding Large Retail Establishment is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standard 4.9.13.O. 1. The proposed exterior work requires a development package. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/05/2025 | Fire New Construction Standard | REVIEW COMPLETED | Alterations to the fire alarm or fire sprinklers requires a separate permit and submittal. CO2 Systems requires a separate Operational Plan. |
||
| 04/22/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |