Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00734
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/02/2024 | Fire New Construction | NOT REQUIRED | |||
06/03/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/30/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1 Provide a complete electrical site plan showing the locations of all solar equipment including the Electrical Service associated with this project. 2 Plan sheet E1.0 shows and states “111 PANELS REMOVED PER SEPERATE DEMOLITION PERMIT. 110 RELOCATED PER PLANS. NEW STRING LAYOUT FOR INVERTER #3”. This is shown within the Rectangle and in bold print. This new string layout shows a total PV count of 302 PV Panels incorporated into 9 PV Strings. Indicate the PV Strings associated with the 110 relocated PV Panels relocated to the new Canopy. Are these 110 relocated PV Panels relocated from the Canopy shown on plan sheet ‘A2.0’ Existing Solar System Canopy per KEYNOTE #2? Please clarify and indicate on the plan. The existing solar Canopy shown on plan sheet ‘A1.0’ does not match the existing Solar Canopy shown on plan sheet ‘A2.0’. Is this the same Canopy? Please clarify. 3a. Indicate or identify the relocated 110 PV Panels by their string # in the new Carport Canopy. 3b. Show all wiring methods associated within the new Carport Canopy and to Inverter #3. This will help clarify the wiring configuration and will help for field inspections. This information can be shown in the PV String configuration, plan sheet E1.0 if desired. 4 Provide a complete grounding detail(s) showing all grounding at the new Carport Canopy complying with NEC art 690 part 5. 5 Please relocate all the large bold print wording across the plan sheet so as not to block the design information or wording and also remove the bold print ‘X’ that renders the KEYNOTES un –legible on plan sheet E2.0, and also Plan sheet E3.0. Ref; 2018 IBC section 107.2.1, 2017 NEC. |
||
06/03/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Sheet S1.0: Please amend plans to remove all 2021 IBC references and instead use 2018 IBC as design code. IBC 107.2.1 Treat as typical note 2. Sheet S2.0: Please amend plans to provide sheet S4.1, as referred to in the detail callouts or amend callout sheet. IBC 107.2.1 3. Structural Calcs page #62 and #63: The connection design summary indicates the Beam Web Compression Buckling Check and Demand Capacity Ration DCR was at 115% capacity and was not shown as OK. Was this resolved? If so, how was it resolved? IBC 107.2.7 Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
05/30/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
05/29/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0424-00734 2547 E BROADWAY BL.– C-1 Relocate 110 panels from 2525 E Broadway to new solar canopy located on new combined lot (1st Review) TRANSMITTAL: May 29, 2024 This site is located in the C-1 zone (4.7.20 ). Mixed use is a permitted use in the zones (UDC Table 4.8-4). 1. As development package TD-DEV-0423-00202 is still open either this DP will need to be revised or completed and a new DP will need to be submitted. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/01/2024 | PDSD Application Completeness | REVIEW COMPLETED |