Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0424-00701
Parcel: 11918086A

Address:
3708 S 16TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0424-00701
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2024 Commercial Electrical APPROVED
05/21/2024 Commercial Mechanical APPROVED
05/20/2024 Site Zoning APPROVED
05/20/2024 Site Engineering NOT REQUIRED
05/22/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
05/22/2024 Commercial Structural REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0424-00701
ADDRESS/PARCEL: (3708 S 16TH AV TUCSON, AZ 85713)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
1. Please provide an EGRESS PLAN - Show the dimension of the overall diagonal of the space per IBC 1007. Provide the distance between required exits. NOTE: egress shall not pass through kitchen, storage or closet per IBC 1016. At each exit, indicate the distance traveled, width of exit and number of individuals exiting.
2. Does fire sprinkler exist.
3. Fire rated wall between Mercantile and Assembly spaces (1 hr if sprinklered, 2 hr if sprinklered).
4. Submit the layout of the retail space, ensure to show the egress path from within this space, etc. Locate the cash register counter, show where power is coming from.
5. Illustrate via a drawing how the ANSI A117.1 is being met when it comes to the height and surface width requirement for the cash register counter.
6. THE MEANS OF EGRESS WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. IBC 1008.2.1 Locate/label the lighted exit sign, emergency light with back-up power as well as the fire extinguisher.
1. Please resubmit.
05/16/2024 Fire New Construction REQUIRES RESUBMIT -Provide door schedule/hardware schedule for all exit doors, including existing doors. Verify required panic hardware.
-Provide a life safety exiting plan.
-Verify if the space has fire sprinklers. Your plans state "no." My records show the building has fire sprinklers.
john.vincent@tucsonaz.gov
5203495581
04/22/2024 PDSD Application Completeness REVIEW COMPLETED