Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00679
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2024 | Commercial Plumbing | APPROVED | |||
| 07/16/2024 | Site Engineering | APPROVED | |||
| 07/08/2024 | Site Zoning | APPROVED | |||
| 07/18/2024 | Commercial Structural | NOT REQUIRED | |||
| 07/18/2024 | Water - PDSD | NOT REQUIRED | |||
| 07/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2024 | Commercial Electrical | REQUIRES RESUBMIT | Permit Review TC-COM-0424-00679 (124 E DELANO ST TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Electrical Review: 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. GFCI protected, E3902.6. >>> Plans show only one 20A kitchen countertop circuit. 2. Show a receptacle outlet within 3’ of each lavatory basin in each bathroom, E3901.6. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. >>> No bathroom receptacle is shown. 3. Provide an updated panel schedule showing wire size of each circuit or notate the wire size for each protection rating, E3702.2. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/13/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |