Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0424-00674
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/15/2024 | Site Zoning | APPROVED | |||
05/15/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/02/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | April 22, 2024 1st Review Architects Studio Inc. Attn: Philip Veneziano 5931 East Pima Street #141 Tucson, Arizona 85712 Re: SPECTRAL INSTRUMENTS IMAGING TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0424-00674 Stantec Project Number: 185215066 Stantec File Number: TUC-24-038 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural and structural designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B II-B 11,750 118 Yes No F-1 24,510 245 S-2 3,530 7 Separate Permits: Automatic fire sprinklers. Deferred Submittals: None. Special Inspections: Epoxy and expansion anchors. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system [2018 IBC Sec. 903] are to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). 2. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. STRUCTURAL COMMENTS Sheet A1.0 1. Please have the engineer of record sign and stamp the sheet which references his structural design. 2. The plan-set and structural calculations are conflicting. Sheet 1 of the structural calculations calls for ¼” thick columns to be used but the plan-set indicates 3/16”. Please revise to match the structural calculations. 3. Details 5 and 6 on the plan-set conflict details 7 and 8. Details 5 and 6 indicate a ¼” thick base plate while 7 and 8 indicate ¾” thick. The calculations call for ¾” thick base plates. Please revise details 5 and 6. 4. The column base plate design at doors is not included in the structural calculations. The dimensions of the base plate differ from what the calculations require. Please provide updated calculations for this design. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
04/23/2024 | Fire New Construction | REVIEW COMPLETED | |||
04/17/2024 | PDSD Application Completeness | REVIEW COMPLETED |