Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0424-00638
Parcel: 11306202B

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0424-00638
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/13/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/13/2024 Commercial Structural REQUIRES RESUBMIT ACTIVITY NO.T C-COM-0424-00638
ADDRESS/PARCEL: (2411 E FORT LOWELL RD TUCSON, AZ 85719)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
1. Detail 2/A-5 – Thank You for providing a curb under the new exterior wall. Provide a zoomed in detail drawings showing the following: “Weep screed shall be provided at or below the foundation plate line on exterior stud walls. The weep screed shall be placed not less than 4 inches above the earth or 2 inches above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The water-resistive barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. Per IBC 2512.1.2 Weep screeds”
2. Detail 1/A-5 - Weep screed shall be provided at or below the foundation plate line on exterior stud walls. The weep screed shall be placed not less than 4 inches above the earth or 2 inches above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The exterior lath shall cover and terminate on the attachment flange of the weep screed. Per IBC 2512.1.2 Weep screeds Where porches, landings, garage aprons are located at same level as floor slab, provide concrete or CMU foundation curb or other approved means to achieve minimum 2 inch clearance between slab and stucco weep screed.
3. Please resubmit.
Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976
04/12/2024 Fire New Construction REQUIRES RESUBMIT -Provide code analysis. Make sure to include fire sprinkler and fire alarm information.
john.vincent@tucsonaz.gov
5203495581
05/10/2024 Site Engineering REQUIRES RESUBMIT 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted in the TDC Online Portal.

Mike Ortiz
michael.ortiz@tucsonaz.gov
05/10/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0424-00638
2411 E FORT LOWELL RD. – R-1
ADD 10' X 11' ROOM UNDER EXISTING PORTICO ROOF (1st Review)

TRANSMITTAL: May 10, 2024
This site is located in the O-3 zone (UDC 4.7.15).

This site is located in the R-1 zone (UDC 4.7.8 Religious Use is a permitted use in this zone (Table 4.8-2).

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf.

2. Until a DP is submitted and approved by all review agencies Zoning cannot approve this plan.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/11/2024 PDSD Application Completeness Express REVIEW COMPLETED