Permit Number: TC-COM-0424-00618
Parcel: 114540650

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.3

Permit Number - TC-COM-0424-00618
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/28/2024 Commercial Plumbing REQUIRES RESUBMIT The operation of the specified lavatory faucet is controlled by a proximity sensor. The requirement is for a metering faucet. [Initial comment: The replacement faucet for the lavatory shall be a metering faucet. The metering faucet shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.11, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.]