Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0424-00585
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT A & TC-COM-0242-00585/UNITS B & C | ||
| 04/10/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/10/2024 11:29:23 AM 1. Sheets S2.0, S2.1: Roof projections less than 2ft of fire separation distance to the line between the buildings are prohibited. Please revise all affected sheets. (2018 IRC section R302.1, Table R302.1(1)) Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/10/2024 11:27:32 AM 1. Sheet C1.1: Include the entire fire separation UL design for the separation wall or walls between units B and C. other sheets show two walls as part of the assembly. Provide the details for the membrane and through penetrations of the separation wall. (2018 IBC section R302.1, R302.4) 2. Sheets C1.1, A1.0.A, A1.0.B: Include the fire rated exterior wall assembly design for the walls with only a one-foot fire separation distance between the two buildings. Roof projections less than 2ft to the imaginary line between the buildings are prohibited. Please revise all affected sheets. (2018 IBC section R302.1, Table R302.1(1)) 3. Sheet C1.1: Include the lists of deferred submittals and special inspections. 2018 IRC section R106) 4. Sheet A1.0.A: The laundry room is labeled as a kitchen. Please revise all affected sheets. (2018 IRC section R106) 5. Sheets A1.0.A, A1.0.B, A1.1.A, A1.1.B: Specify the windows in hazardous locations that are safety glazed. (2018 IRC section R308.4) 6. Sheets A1.1.A, A1.1.B: Include the U-Factors of the windows and doors. Show the window clear openings meeting the egress requirements of the 2018 IRC section R310. (2018 IECC section R402) Sheets A3.0.A, A3.0.B: Include the wall and ceiling insulation R-Values showing compliance with the 2018 IECC section R402. Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/10/2024 11:28:37 AM 1. Manual J and S calculation reports: Provide the reports for each unit, label which unit the reports are for, and include the equipment details corresponding with the calculation results. (2015 IECC section R403.7) 2. Sheets M1.01, M1.02: Detail the bathroom exhaust fans vent to the exterior. (2018 M1505.2) 3. Sheets M1.01, M1.02: Show the location of the dryer exhaust vents and their distances from openings. (2018 IRC section M1502) 4. Sheets M1.01, M1.02: Show the walkway and platform for the HVAC equipment in the attics. Include the drawings showing the drain pans and condensate drain piping. (2018 IRC section M1305.1.2) Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/10/2024 11:28:06 AM 1. Sheets C1.1, E2.02, E3.02: Include the electric vehicle charging station on the panel schedules, plans, and calculations. (2018 IRC section R106) 2. Sheet E2.01 (One-Line Diagram): Show the correct voltage for the electrical service as detailed in the panel schedules. Show the locations of all electrical equipment, rating of the meter, service entrance conductors, and proper grounding electrode conductors for both buildings. (2018 IRC section R106) 3. Sheet E2.02: Include the site panel schedule and calculations. (2018 IRC section R106) 4. Sheets E3.01, E3.02: Show the closet light details and distance to the storage spaces. (2017 NEC sections 410.2, 410.16) 5. Sheets E3.01, E3.02, E4.01, E4.02: Show the locations of all electrical service equipment. (2018 IRC section R106) 6. Sheet E4.01: Missing receptacles on the counter above the dishwasher, within 6ft of the start of the wall in the laundry room, and bedroom #4. (2017 NEC section 210.52) 7. Sheet E4.02: Missing receptacles on the dining room wall next to the door in both units, within 6ft of the door in the living rooms in both units, and for the refrigerator. (2017 NEC section 210.52) 8. Sheet E4.02: The Exterior receptacles are not identified as being GFCI protected. (2017 NEC section 210.8) 9. Sheet E4.02: The exterior receptacles are not identified as being GFCI protected. (2017 NEC section 210.8) Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 4/10/2024 11:29:04 AM 1. Sheets P1.01, P1.02, P2.01, P2.02: Provide the plumbing supply piping and DWV piping isometric diagrams. (2018 IRC section R106) 2. Sheets P2.01, P2.02: Detail the reason for the 2” drain piping located on the exterior of the buildings. 3. Sheet P4.01: Specify the model of water heaters being installed. (2018 IRC section R106) |
||
| 04/25/2024 | Site Engineering | REQUIRES RESUBMIT | The building permit cannot be approved until the associated development package, TD-DEV-0324-00066, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 04/30/2024 | Site Zoning | REQUIRES RESUBMIT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT A & TC-COM-0242-00585/UNITS B & C ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0424-00577 & TC-COM-0242-00585 - TD-DEV-0324-00066 526 N WESTMORELAND AV. Units A, B & C – R-2 Multifamily (1st Review) TRANSMITTAL: April 30, 2024 This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. Development Package, TD-DEV-0324-00066, is approved by all review agencies Zoning cannot approve these building plans. 2. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the highest point of the wall meets the eave of the roof. As dimensions were not provided from design grade to the highest point of the wall Zoning cannot determine setback requirements. 3. Sheet 3, Design Plan-Building A the plan calls out “KITCHEN 1” in what appears to be the laundry room, clarify what this room is. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/01/2024 | Water - PDSD | REQUIRES RESUBMIT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT A & TC-COM-0242-00585/UNITS B & C 1. Provide a site plan showing the location of the water meter and the route of the water service to the building. Specify the material of construction for the water service pipe. Reference: Sections 107.2.1 and 107.2.6, IBC 2018. 2. Provide calculations for the water demand served by each water meter and showing how the water supply piping has been sized. Verify that the pipe sizes will not result in water velocities greater than those recommended by the pipe manufacturer (e.g. limit the water velocity to less than 8 FPS for copper, PEX, or CPVC piping). Reference: Sections 604.1 and 604.3, IPC 2018. 3. Provide water shut off valves for each dwelling unit, accessible within the dwelling unit it serves. Reference: Section 606.1, IPC 2018. |
||
| 04/08/2024 | Fire New Construction | REVIEW COMPLETED | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT A & TC-COM-0242-00585/UNITS B & C | ||
| 04/02/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |