Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0423-01167
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2023 | Water - PDSD | APPROVED | -Shared Studio Session on 819-730-868 Master Permit PLANS UNDER TC-COM-0423-01167 /LEASING OFFICE, TC-COM-0523-01240/BLDG A, TC-COM-0523-01241/BLDG B, TC-COM-0523-01242/BLDG C | ||
| 06/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | -Shared Studio Session on 819-730-868 Master Permit PLANS UNDER TC-COM-0423-01167 /LEASING OFFICE, TC-COM-0523-01240/BLDG A, TC-COM-0523-01241/BLDG B, TC-COM-0523-01242/BLDG C | ||
| 05/31/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0423-01167 / TC-COM-0523-01240 / TC-COM-0523-01241 / TC-COM-0523-01242 GENERAL: ⦁ Provide written responses to all review comments. ⦁ Provide a complete plan set. ⦁ Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 5/31/2023 4:51:38 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 5/23/2023 4:35:56 PM 1. Sheet G1.02: Provide the location of egress illumination and exit lighting in accordance with Section 1008 and 1013. 2. General: Fire resistant wall/floor assemblies and penetrations typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly and penetration details. 3. General: Exercise equipment is required have clear floor space for access. Ensure clear floor space in accordance with Section 236.1 of the 2010 ADAAG. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Denied Reason: Date Completed : 5/17/2023 9:52:04 PM 1. Where bathroom, dryer, kitchen exhaust duct's and outdoor fresh air duct penetrates the fire rated floor/ceiling assembly it shall be protected in an approved manner in accordance with this section in all apartment unit's (IMC2018,607.6.2) 2. Provide ceiling radiation dampers at all ceiling supply diffuser's, provide the symbol on the plan and note it on the same page in all apartment unit's (IMC2018,607.6.2) 3. Only fire dampers and ceiling radiation dampers labeled for use in dynamic systems shall be installed in HVAC systems designed to operate with fans on during a fire event in all apartment units (IMC2018,607.3.1) 4. Provide kitchen exhaust to building D IMC2018,403.3) 5. Provide make up air for laundry room approximately equal the the total dryer exhaust rate in an approved manner (IFGC2018,614.5) Electrical(E) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 5/21/2023 7:37:40 PM NEC 210.52(A)(1) requires that no point along the wall line be more than 6 feet from a receptacle outlet in dwelling units. Provide exit signs, emergency lighting, and egress lighting in amenities building. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/24/2023 6:42:23 PM First plumbing Review: 1). Roof parapet wall on plan pages A1.14, A1.24, A1.34, A1.42 needs secondary scuppers compliant with IPC 1106.5 & 1108, only primaries shown - 2). laundry room sanitary illustration on plan page P1.03 is missing the required floor drain & trap primer as shown on plan page A1.40 -IPC 413.4 3). add a note to the apartment fixture schedules on plan page P5.00 to match note#6 from building D fixture schedule same page - IPC 303.3, 402 4). Plan set submittal needs to be accompanied by the civil site utility piping plan for the continuation & correlation of the water, storm & sewer. -IPC 106.3.1 5). Add the DFU total load notation next to the Building drain exits on plan pages -P1.00, P1.01, P1.02, P1.03 -IPC 710 6). Add lint interceptor model number & manufacturer name to detail 208 on plan page P4.00 -IPC 303, 1, 1003.6 |
||
| 05/23/2023 | Site Engineering | REQUIRES RESUBMIT | See Zoning Comment | ||
| 05/18/2023 | Site Zoning | REQUIRES RESUBMIT | -Shared Studio Session on 819-730-868 Master Permit PLANS UNDER TC-COM-0423-01167 /LEASING OFFICE, TC-COM-0523-01240/BLDG A, TC-COM-0523-01241/BLDG B, TC-COM-0523-01242/BLDG C FROM: PDSD Zoning Review Section PROJECT: TC-COM-0423-01167 – Leasing Office, TC-COM-0523-01240 – Bldg A, TC-COM-0523-01241 – Bldg B & TC-COM-0523-01242 – Bldg C 8411 S. Houghton Rd – R-2 Multifamily (1st Review) TRANSMITTAL DATE: May 18, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in the zone, (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. COMMENT: Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0123-00111 and although it appears that the plans match until the DP is approved by all review agencies Zoning cannot approve the building plans. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/13/2023 | Fire New Construction | REVIEW COMPLETED | -Shared Studio Session on 819-730-868 Master Permit PLANS UNDER TC-COM-0423-01167 /LEASING OFFICE, TC-COM-0523-01240/BLDG A, TC-COM-0523-01241/BLDG B, TC-COM-0523-01242/BLDG C | ||
| 05/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | -Shared Studio Session on 819-730-868 Master Permit PLANS UNDER TC-COM-0423-01167 /LEASING OFFICE, TC-COM-0523-01240/BLDG A, TC-COM-0523-01241/BLDG B, TC-COM-0523-01242/BLDG C |