Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-01162
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/18/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/05/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0423-01162 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 7/4/2023 12:07:07 AM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 7/4/2023 12:06:14 AM Provide a COMCheck or other mythology to verify envelope compliance in accordance to 2018 IECC C402. Response: Comcheck provided with this submittal. Please indicate the location of the COMCheck document, it was not found found on the drawings nor in the items submitted Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 7/4/2023 12:06:48 AM Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 7/4/2023 12:06:28 AM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 7/1/2023 11:23:49 PM Second Plumbing Review: 1). SAME-Plan page A4.0 needs to include primary & secondary scupper locations along with detail & sizing calculations.-IPC 1106.1, 1106.5, 1108 2).SAME- Plan page A4.0 needs to include downspout sizes along with GPM loads - IPC 1106.3 3). OK 4).OK 5). SAME-add mop sink & faucet manufacturer & model number to FS 2.1 or P6.0 currently states "provided by GC" -IPC 303 6). OK |
||
07/18/2023 | Water - PDSD | REQUIRES RESUBMIT | Comment not addressed. [Initial comment: Coordinate the civil and plumbing plans. The civil plans call for a 2” water meter, 2” RP, and a 2” water service to the building while the plumbing plans call for a 1” water meter, 1-1/2” RP, and a 1-1/2” water service to the building.] | ||
06/28/2023 | PDSD Application Completeness | REVIEW COMPLETED |