Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0423-01157
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/16/2023 | Site Zoning | APPROVED | |||
05/23/2023 | Site Engineering | NOT REQUIRED | |||
06/21/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/21/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0423-01157 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Denied Reason: Date Completed : 6/21/2023 10:37:12 AM 1. Refer to Structural Calculations submitted; the calculations show conveyors supports at certain c/c spacing. No locations on Plan are shown for these supports. Provide Structural Drawing showing locations of the supports. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/14/2023 3:24:29 AM 1. Clarify if this conveyor system replaces an existing conveyor. If so, show the layout of the old conveyer or indicate the upgrade did not change the layout. Update the scope of work to indicate new or replacement systems. 2. Provide a floor plan of the warehouse and show any additional existing equipment or racking. It is unknown if the conveyer creates exiting issues for the existing space such as dead end corridors. 2018 IBC 1020.4. 3. Provide an occupancy count on the egress plan for the warehouse. 2018 IBC 1004.5 4. Provide an enlarged floor plan for the area where the new air compressor units are located. Clarify if this compressor replaces an existing unit. 5. A sheet index is provided however the drawings are not labeled as such and it is confusing. Coordinate the drawings and the details so the information is consistent or separate out the manufactures shop drawings from the architectural drawings. 6. Clarify if there is to be any new electrical installed or electrical connections as part of this submittal. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/6/2023 10:43:10 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 6/9/2023 2:07:12 PM Electrical Review By: Ron Ross PE No electrical drawings or information provided. An Electrical permit is denied. Equipment installation may not actually require an electrical permit. Consult with local AHJ. |
||
05/24/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/05/2023 | PDSD Application Completeness | REVIEW COMPLETED |