Permit Number: TC-COM-0423-01141
Parcel: 131040480

Address:
5010 E 23RD ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0423-01141
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/24/2023 Site Engineering APPROVED
05/24/2023 Site Zoning APPROVED
06/14/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/14/2023 Commercial Structural REQUIRES RESUBMIT Please respond to the following:
A. Permit T21CM01948 Addition Kitchen; Bedroom and Patio is not complete. This permit must be approved and inspected prior to this permit TC-COM-0423-01141 being processed. No further activity on this permit until T21CM01948 is complete.
B. BUILDING REVIEW: Assuming that you are able to resolve the zoning issues with the Zoning Department, ensure you obtain approval on the Request for Zoning Authority Clearance & submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. NOTE: R-3 maximum allowable is 5 clients & R-4 maximum allowable is 10 clients (Indicate the Occupancy Classification, the number of clients on your drawings as well as indicate whether it is Group Home, Behavioral Health, Assisted Living, Day Care, etc.). Include a statement as part of your code analysis as to how the facility handles any persons receiving custodial care who require limited verbal or physical assistance responding to an emergency situation to complete building evacuation and self preservation. Specify Condition 1 or Condition 2 per IBC 310 (this will determine the type of fire sprinkler system the fire department will require). 1. On the Site Plan show/indicate the Accessible route from drop off location to the entry door complying to ANSI A117. In an Emergency, show/locate the gathering area where it is safe from danger IBC 310.5. 2. Indicate the clear opening of the doors complying to ANSI A117. 3. Indicate the clear width of hallways. 4. Show/locate the two grab bars at the Water Closet as well as the two grab bars at the Shower, make sure to indicate the installation of Structural Backer Board for these grab bars. 5. Provide Emergency Escape & Rescue Openings per IRC R310 at every bedroom/sleeping space. On the drawing adjacent to the opening(s), indicate the clear opening for both horizontally and vertically and provide the dimension from the finish floor to the bottom of the opening. Indicate if there are obstacles on either side of the opening. 6. Fire Sprinkler is required and processed as a separate permit. Submit the drawings to the Fire Department for review and approval. They will conduct fire inspection, their approval will be required before issuing the Certificate of Occupancy. 7. Electrical work (conductors/wiring/breaker ONLY) related to the installation of Emergency Lights, Lighted Signs, Audible Fire/Smoke Alarms shall also be reviewed as part of this permit & will be inspected by City of Tucson inspectors. Any new renovation work must be included as part of this building permit. 8. A Final inspection will be conducted by our inspectors prior to issuance of the Certificate of Occupancy. 9. An Operator's License must be applied for with the State, the absence of this license shall void this building permit. 10. Submit a copy of the State License application as part of the permit submittal. 11. If you have any questions, contact Justin Eder at Justin.Eder@tucsonaz.gov or at 520-837-4976.
05/18/2023 Fire New Construction REQUIRES RESUBMIT Per 2018 IFC R-3 Occupancy as it applies to "Care Facilities" is limited to 5 or fewer occupants. Please revise Occupancy or limit care to 5 or fewer on your plan set.
Questions: patricia.shelton@tucsonaz.gov
05/09/2023 PDSD Application Completeness Express REVIEW COMPLETED