Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0423-01139
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/02/2023 | Water - PDSD | APPROVED | |||
06/02/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/17/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/17/2023 2:53:28 AM 1. Clarify what deferred submittals will be provided for this project as noted on sheet G002. Only the signage is noted, however the structural drawings indicate wood trusses will be deferred and the “canopy by others” as noted on the drawings is unknown. 2. Provide a signed copy of the COMcheck for the envelope compliance report. 3. Update general note 34 on sheet G002 to indicate that Fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/17/2023 2:54:22 AM 1. Provide a mechanical roof plan for the project. Indicate the distance to the roof edge from the new RTU. If the distance is less than 10 feet, indicate how fall protection will be provided in accordance with the IMC and 2018 IBC 1015.6. (The height of the parapet is unknown). Include the location of the proposed location of the walk in and ice maker CU that is shown on the electrical roof plan. 2. Provide a roof curb detail for the new units on the drawings Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/17/2023 2:53:56 AM 1. Indicate on the drawings that all exterior lighting will be in compliance with the Tucson/ Pima county ordinance. Provide the calculations that indicate the new exterior lighting is in compliance based on this ordinance. 2. Provide an interior lighting COMcheck or other approved methodology for the project for the new proposed lighting that is in compliance with the 2018 IECC, not the 2021 IECC. Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/17/2023 2:54:44 AM 1. Provide a site plan that indicates the location of the public water and sewer lines that the new building will connect into. Indicate the location and size of the water meter. |
||
05/18/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
05/12/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0423-01139 - TD-DEV-0423-00210 2402 N 1st Ave. – C-1/C-2 Black Rock Coffee Bar (1st Review) TRANSMITTAL: March 12, 2023 This site is located in C-1/C-2 zone (UDC 4.7.20 & 4.7.21), Food Service is an allowed use in the zones (UDC Table 4.8-4) subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O and 4.9.4.M.1 and 4.9.13.P 1. As development package (DP) TD-DEV-0423-00210, has not completed its first review Zoning cannot review the building plans at this time and will review for compliance on the next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/01/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/01/2023 | PDSD Application Completeness | REVIEW COMPLETED |