Permit Number: TC-COM-0423-01076
Parcel: 135084450

Address:
1345 S KOLB RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0423-01076
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2023 Commercial Mechanical APPROVED
05/16/2023 Commercial Plumbing APPROVED
05/18/2023 Commercial Structural APPROVED APPLY FOR A SEPARATE PERMIT FOR THE ALUMI-LATTICE RAMADA(S). SUBMIT THE STRUCTURAL DESIGN DRAWINGS AND THE STRUCTURAL CALCULATIONS THAT ARE BOTH SEALED/SIGNED BY AN ARIZONA REGISTERED STRUCTURAL ENGINEER.
05/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/15/2023 Commercial Electrical REQUIRES RESUBMIT 1 Verify compliance with the 2012 City of Tucson Outdoor Lighting Code for the Pool/Spa lighting. See sections 401.2.1(2) and 402.1.

2 The panel schedules do not reflect the GFI protected Pool/Spa equipment and lighting per NEC art 680. And NEC art 408.4.

3 Show the location of the Maintenance Disconnect and Emergency Power Off. NEC 680.13 and 680.41.

4 Show the locations of the Pool/Spa panelboards and equipment layout.

Ref; 2018 IBC section 107.2, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code.
05/10/2023 Site Engineering REQUIRES RESUBMIT See zoning comment
05/04/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-COM-0423-01076
1345 S KOLB RD Zoning C-2

TRANSMITTAL DATE:‎May 4, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Zoning has reviewed the building plan for compliance with unapproved TD-DEV-0323-00189 , Zoning cannot approve the building plans until the DP is approved.


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
04/26/2023 Fire New Construction REVIEW COMPLETED
04/26/2023 PDSD Application Completeness Express REVIEW COMPLETED