Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-00975
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/18/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | MASTER SET LOCATED AT: STUDO SESSION 518-759-204, TC-COM-0323-00830 (7355 S WILMOT RD Unit:BLDG 19 TUCSON, AZ 85756) WITH REVIEW NOTES TO BE COPIED ON TC-COM-0423-00974 (7355 S WILMOT RD Unit:BLDG 18 TUCSON, AZ 85756), TC-COM-0423-00975 (7355 S WILMOT RD TUCSON, AZ 85756) & TC-COM-0423-00976 (7355 S WILMOT RD TUCSON, AZ 85756) | ||
12/18/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 10/23/2023 9:27:57 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 10/23/2023 1:22:51 PM Mechanical N/A Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 10/23/2023 11:32:30 AM Electrical Review By: Ron Ross PE Updated the Dog Wash Station location is missing keynote 13 on sheet ES102 The added electrical layout for ‘RAMADA-1’ is detail #4 not #3 as shown on ES103 Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 12/17/2023 10:09:49 PM Second Revision Plumbing Review: 1).Unresolved- Total gas load on plan page P1.1 needs to be updated to reflect new total load -IFGC 402 ** Total Load should be 2085 CFH** 2), Unresolved-Total Gas load on plan P2.2 is incorrect -IFGC 402 ** Total Load should be 2085 CFH** 3). Unresolved-Provide product spec info for the K9000 truBlu dog washer liste on plan page P4.1 , A High hazard Backflow will be required, Per the product website the hand sprayer can be located below flood rim & unit has shampoo & flee bath injection options - IPC 608 ** Backflow info not provided** 4). Resolved-Provide letter from utility authority that allows the pet fountain drain to potentially collect storm water or provide protection on plan page P1.4 -IPC 1101.3 5). Resolved-Dog washer on P1.2 & P4.1 needs hot water -IPC 607.1 |
||
12/12/2023 | PDSD Application Completeness | REVIEW COMPLETED |