Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0423-00960
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/03/2023 | External Reviewers - SAFEBuilt | APPROVED | Activity Number: TC-COM-0423-00960 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 5/23/2023 4:51:12 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 5/17/2023 2:37:41 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 5/10/2023 6:32:19 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 6/29/2023 6:14:42 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 7/1/2023 11:02:23 PM Second Plumbing Review: Ok subject to field inspections & utility authority see comment #1 1). OK-The 3 compartment sink floor sink, the coffee cappuccino floor sinks, & service sink Plan page P1.0 needs to discharge thru an grease interceptor due to foods & coffee/cappuccino being prepared as shown on plan page A1.2 or provide letter from Utility authority that grease interceptor will not be required for this facility. -IPC Chapter 10 Tucson Amendments ** Email uploaded from utility authority PIMA stating grease interceptor not required** Subject to Field inspections 2). OK- Gas notes removed=no gas work 3). OK 4).OK |
||
07/07/2023 | Site Engineering | NOT REQUIRED | |||
07/07/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
07/05/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Iman Monshizadeh / PDSD Zoning Review Section PROJECT: TC-COM-0423-00960 / Convenience store remodel Plot Plan Review (3rd Review) 1306 W Grant Rd / I-1 Zone TRANSMITTAL DATE: 7/05/2023 Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: The square footage of the building addition shown on the building plans (1689sf) is greater than the square footage shown on the Development Package DP21-0247 (1641sf). Either the floor area on the building plans will need to be adjusted or the development package will need to be revised to reflect the floor area of the structure. Zoning cannot approve until the floor area shown on these documents match. Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
06/29/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |